@@ -6,7 +6,7 @@ Depending on your settings you can open Config Builder through a tab at the top
6
6
7
7
The **Config Builder** is the tab where you turn the modular features on and off. In the picture below, the boxes on the left-hand side (A) allow you to select which modules you want activated. By default, when opening the Config Builder, sections are collapsed to only show the active plugins. Click on the arrow (G) to show all available options. The boxes on the right-hand side (C) allow you to view the active modules as a tab (E) in **AAPS**. In case the right box is not activated, you can reach the function by using the hamburger menu (D) on the top left of the screen. See [Tab or hamburger menu](#tab-or-hamburger-menu) below.
8
8
9
-
When there are additional settings available within the module, you can click on the cog wheel (B) which will take you to the specific settings within preferences.
9
+
When there are additional settings available within the module, you can click on the cog wheel (B) which will take you to the specific settings within __Preferences__.
10
10
11
11

12
12
@@ -43,24 +43,24 @@ More information to understand the Insulin Profile as shown in **AAPS** [here](#
43
43
### Insulin type differences
44
44
45
45
* The options 'Rapid-Acting Oref', Ultra-Rapid Oref', 'Lyumjev' and 'Free-Peak Oref' all have an exponential shape.
46
-
* For 'Rapid-Acting', 'Ultra-Rapid' and 'Lyumjev' the DIA is the only variable you can adjust by yourself, the time to peak is fixed.
47
-
* Free-Peak allows you to adjust both the DIA and the time to peak, and must only be used by advanced users who know the effects of these settings.
46
+
* For 'Rapid-Acting', 'Ultra-Rapid' and 'Lyumjev' the __DIA__ is the only variable that can be adjusted, the time to peak is fixed.
47
+
* Free-Peak allows you to adjust both the __DIA__ and the time to peak, and must only be used by advanced users who know the effects of these settings.
48
48
* The [insulin curve graph](#AapsScreens-insulin-profile) helps you to understand the different curves.
49
49
50
50
#### Rapid-Acting Oref
51
51
52
52

53
53
54
54
* recommended for Humalog, Novolog and Novorapid
55
-
*DIA = at least 5.0h
55
+
*__DIA__ = at least 5.0h
56
56
* Max. peak = 75 minutes after injection (fixed, not adjustable)
57
57
58
58
#### Ultra-Rapid Oref
59
59
60
60

61
61
62
62
* recommended for FIASP
63
-
*DIA = at least 5.0h
63
+
*__DIA__ = at least 5.0h
64
64
* Max. peak = 55 minutes after injection (fixed, not adjustable)
65
65
66
66
(Config-Builder-lyumjev)=
@@ -76,8 +76,8 @@ More information to understand the Insulin Profile as shown in **AAPS** [here](#
76
76
77
77

78
78
79
-
* With the "Free Peak 0ref" profile you can individually enter the peak time. To do so click to cogwheel to enter advanced settings.
80
-
* The DIA is automatically set to 5 hours if it is not specified higher in the profile.
79
+
* With the "Free Peak 0ref" profile you can manually enter the peak time. To do so click to cogwheel to enter advanced settings.
80
+
* The __DIA__ is automatically set to 5 hours if it is not specified higher in the profile.
81
81
* This effect profile is recommended if an unbacked insulin or a mixture of different insulins is used.
82
82
83
83
(Config-Builder-bg-source)=
@@ -160,7 +160,7 @@ This module should not be disabled as it is a core part of **AAPS**.
160
160
161
161
### Objectives
162
162
163
-
**AAPS** has a learning program (a series of objectives) that you have to fulfill step by step. This should guide you safely through setting up a closed loop system. It guarantees that you have set everything up correctly and understand what the system does exactly. This is the only way you can trust the system.
163
+
**AAPS** has a learning program (a series of objectives) that you have to fulfill step by step. This should guide you safely through setting up a closed loop system.
164
164
165
165
See [Objectives](../SettingUpAaps/CompletingTheObjectives.md) page for more information.