Interpreting Pylontech BMS data

What every metric means, what's normal, and what flags a failure.

Disclaimer: This guide is offered as informational context only — a health-check aid, not an official assessment. The author accepts zero liability for any decision made from this guide. If a pack looks faulty, your installer or Pylontech are the right people to advise. See the project LICENSE.


The headline indicator: cell-voltage spread

In any series-connected lithium pack, all cells carry the same current. So at any moment, each cell's voltage reflects its individual state-of-charge and its internal resistance. In a healthy pack, all cells track each other very closely — a few millivolts apart.

When a cell starts to fail (capacity loss, increased internal resistance, or both), it deviates from its siblings under load.

Thresholds (under moderate load, 1–5 A)

Spread Meaning Toolkit verdict
< 30 mV Healthy — normal cell-to-cell variance HEALTHY
30–50 mV Emerging imbalance — worth monitoring DEGRADING
> 50 mV At least one cell has a fault — IR rise, capacity loss, or both FAILED

Pylontech US3000C / US5000 use 15-cell LFP series strings. Each cell sits around 3.30–3.32 V at mid-SOC under light load. Healthy spreads are typically 1–5 mV. A 100 mV spread means one cell is 100 mV away from the rest, which is a strong sign of a failed cell.

Important caveat: at very low or very high SOC, the LFP voltage curve steepens dramatically, so spreads above 30 mV are normal at the very ends of charge / discharge. Best to read spread when the pack is between 20 % and 80 % SOC under light-to-moderate current.


The other definitive indicator: BMS-reported SOH

The Pylontech BMS computes its own State of Health internally and exposes it via the stat command's SOH field (a percentage).

stat → SOH Meaning
99–100 Normal
70–98 Degraded but functional
1–69 Significant capacity loss
0 The BMS has declared the pack end-of-life — the strongest single end-of-life signal.

The toolkit treats SOH = 0 as forcing a FAILED verdict regardless of any other metric, because the BMS itself has spoken.


The runtime alarm: pwr → Soh. Status

The pwr command shows a real-time Soh. Status field that indicates whether the BMS is currently flagging an SOH alarm:

  • Normal — no current alarm
  • Abnormal — alarm is active right now

The toolkit forces FAILED when this is Abnormal.

Note: this flag can come and go depending on operating conditions, while stat → SOH is a more stable lifetime metric.


Per-cell SOH counters

The soh N command lists each cell with two columns:

  • SOHCount — number of times the BMS has flagged that cell as "abnormal" over the lifetime of the pack
  • SOHStatus — the cell's current status flag (Normal / Abnormal)

Any cell with SOHCount > 0 has been flagged at some point. Counts in the hundreds indicate sustained, repeated abnormal events on that specific cell — a clear localised failure indicator.

Comm-bus limitation: when soh N is queried via the master pack against a slave pack, SOHCount values often come back as 0 even when the slave's own local query shows non-zero counts. The pack-level Soh. Status: Abnormal does propagate. To get authoritative per-cell SOHCount data, plug the cable directly into the suspect pack's console port.


Real cycle count vs charge transitions

The stat command exposes two cycle-related numbers and they are not the same thing:

Field What it actually counts
CYCLE Times True full-equivalent charge cycles. This is the meaningful real-cycle metric.
Charge Times A transition counter (BMS state changes that include charge events). Often an order of magnitude higher than the real cycle count. NOT a real cycle count — don't mistake it for one.

A US3000C is rated for 6 000+ cycles to 80 % capacity under nominal conditions. A pack failing at < 1 000 real cycles is failing well short of rated life.


Per-cell capacity tracking (data event)

The data event command shows the most recent stored event with a per-cell snapshot. A column called Coulomb shows each cell's tracked capacity as a percentage of nominal:

Cell coulomb % Meaning
90–95 % Normal mid-life cell
70–89 % Cell is losing capacity
< 70 % Significant capacity loss — this cell is failing

A cell can have normal voltage at idle but a low coulomb % — meaning its capacity has shrunk, but at any given SOC its voltage still looks fine. These cells will fail "high" (over-voltage) at the top of charge before any voltage spread is visible at idle.

This is why looking at voltage spread alone is not sufficient — a pack can have one cell sagging under load (voltage indicator) and a different cell with capacity loss (coulomb indicator) at the same time. The toolkit shows both.


Lifetime alarm trip counts

stat field Meaning What non-zero values indicate
Bat OV Times Cell over-voltage protection trips High — top cell hit ~3.60 V; usually due to imbalance at end of charge
Bat HV Times Cell high-voltage warnings Less critical than OV but same root cause
Bat LV Times Cell low-voltage warnings Bottom cell sagging at end of discharge
Bat UV Times Cell under-voltage protection trips Same as LV but at the harder cutoff threshold
COC / DOC Times Charge / discharge over-current trips Abuse indicator — if non-zero, possibly mis-sized inverter or fault current event
SC Times Short-circuit trips Abuse indicator — should be 0 on a healthy install
Shut Times Pack shutdowns High counts → BMS frequently throwing in the towel
Reset Times BMS resets High counts → instability

For a health assessment, abuse indicators (COC, DOC, SC) being all 0 is good news — it shows the pack was not over-stressed. Voltage-only trips (OV, HV, LV, UV) are not abuse, they are the BMS protecting itself from imbalanced cells.


Putting it together — failure signatures

Classic high-IR cell

  • One cell sags under load (voltage spread > 50 mV during discharge)
  • That cell recovers towards the pack mean at idle
  • BMS triggers BLV (low-voltage) alarms during heavy discharge
  • Voltage spread visible in bat N

Classic capacity-loss cell

  • Cell looks fine on voltage — within a few mV of pack mean at all SOCs
  • data event Coulomb column shows that cell at a much lower percentage
  • BMS triggers BHV / BOV at end of charge as that cell fills first
  • Sometimes shows up via SOHCount creeping up over months

A failing pack typically has both

Most failing Pylontech packs we've examined have at least one cell of each type — a high-IR cell pinching the bottom of the curve and a capacity-loss cell pinching the top. Hence the toolkit checks both bat and data event and includes both in the health report.

Batch defects

When you see multiple packs from the same production batch (sequential serial numbers, identical release date) showing the same failure mode in the same rack, that is a strong signal of a batch issue rather than independent end-of-life. Worth noting that pattern if you discuss the rack with your installer or Pylontech.