⚠ EXAMPLE DATA — ALL VALUES BELOW ARE FICTIONAL.
This document exists so a visitor can see the report format before installing the tool. Every barcode, date, voltage, statistic and event listed below is invented for illustration. Any resemblance to a real pack, real installation or real customer data is coincidental.
Report generated: YYYY-MM-DD Verdict: FAILED
Important — please read first
This report was generated by the pylontech-battery-health toolkit, an unofficial community tool. It is not affiliated with, endorsed by or warranted by Pylontech Technology Co. Ltd or any of its distributors.
The data below was read directly from the battery's own BMS via its native console interface. No values have been altered. The verdict is computed against published cell-imbalance and SOH thresholds.
This is a health check, not an official assessment. The author of this tool accepts zero liability for any decision, action or outcome arising from use of this report. If a pack looks faulty, your installer or Pylontech are the right people to advise on next steps.
| Model | US3000C |
| Barcode (serial) | EXAMPLE-FICTIONAL-SERIAL |
| Specification | 48V/74Ah |
| Release date | YY-MM-DD |
| Main software version | V1.x |
| Pack address in rack | N |
| Cell count | 15 |
- Cell-voltage spread XX mV exceeds 50 mV failure threshold
- Pack voltage: 49.XX V
- Pack current: -X.XX A (Dischg)
- Pack temperature: XX.X °C
- Pack SOC (Coulomb): XX %
- Cell-voltage spread: XX mV (< 30 mV healthy, 30–50 mV degrading, > 50 mV failed)
- Runtime
Soh. Statusflag: Normal
| Cell | Voltage (mV) | Δ from max (mV) | SOC | SOH-abnormal events | SOH status |
|---|---|---|---|---|---|
| 0 | XXXX (weakest) | −XX | XX % | XX | Abnormal |
| 1 | XXXX | −X | XX % | 0 | Normal |
| 2 | XXXX | −X | XX % | 0 | Normal |
| 3 | XXXX | −X | XX % | 0 | Normal |
| 4 | XXXX | 0 | XX % | 0 | Normal |
| ... | ... | ... | ... | ... | ... |
| Metric | Value | Notes |
|---|---|---|
| BMS-reported SOH | XX % | 0 % = pack declared end-of-life by its own BMS |
| SOH-abnormal events accumulated | XXX | progressive degradation indicator |
| Real charge cycles | XXX | the meaningful real-cycle metric (CYCLE Times) |
| Charge transitions | XXXX | NOT real cycles — partial-event counter (Charge Times) |
| Cell over-voltage trips (BOV) | X | |
| Cell low-voltage warnings (BLV) | XX | |
| Pack shutdowns | X | |
| BMS resets | X |
- Item Index: XX
- Time: YYYY-MM-DD HH:MM:SS
- Voltage: XXXXX mV
- Current: -XXXX mA
- Percent: XX %
- Bat Events: Cell low-voltage warning (cell N)
Raw command output, straight from the BMS, for full traceability:
@
info N
Manufacturer : Pylon
Device name : US3000C
Board version : EX0XX-EX0XX-EX-EX
Main soft version: V1.x
Soft version : V2.x
Boot version : V1.x
Comm version : V2.x
Release date : YY-MM-DD
Barcode : EXAMPLE-FICTIONAL-SERIAL
Specification : 48V/74Ah
Cell number : 15
Address : N
Command completed successfully
$$
(further raw captures truncated for sample — real reports include verbatim pwr, bat, soh, stat and data event output for full traceability)
Generated by pylontech-battery-health. All BMS counters and statuses in a real report are authoritative from the pack's own BMS hardware; no third-party measurement is used.