Pylontech US3000C — Diagnostic Report (sample)

⚠ EXAMPLE DATA — ALL VALUES BELOW ARE FICTIONAL.

This document exists so a visitor can see the report format before installing the tool. Every barcode, date, voltage, statistic and event listed below is invented for illustration. Any resemblance to a real pack, real installation or real customer data is coincidental.

Report generated: YYYY-MM-DD Verdict: FAILED


Important — please read first

This report was generated by the pylontech-battery-health toolkit, an unofficial community tool. It is not affiliated with, endorsed by or warranted by Pylontech Technology Co. Ltd or any of its distributors.

The data below was read directly from the battery's own BMS via its native console interface. No values have been altered. The verdict is computed against published cell-imbalance and SOH thresholds.

This is a health check, not an official assessment. The author of this tool accepts zero liability for any decision, action or outcome arising from use of this report. If a pack looks faulty, your installer or Pylontech are the right people to advise on next steps.


Pack N — US3000C — FAILED

Identification

Model US3000C
Barcode (serial) EXAMPLE-FICTIONAL-SERIAL
Specification 48V/74Ah
Release date YY-MM-DD
Main software version V1.x
Pack address in rack N
Cell count 15

Verdict reasoning

  • Cell-voltage spread XX mV exceeds 50 mV failure threshold

Live readings (at time of test)

  • Pack voltage: 49.XX V
  • Pack current: -X.XX A (Dischg)
  • Pack temperature: XX.X °C
  • Pack SOC (Coulomb): XX %
  • Cell-voltage spread: XX mV (< 30 mV healthy, 30–50 mV degrading, > 50 mV failed)
  • Runtime Soh. Status flag: Normal

Per-cell readings

Cell Voltage (mV) Δ from max (mV) SOC SOH-abnormal events SOH status
0 XXXX (weakest) −XX XX % XX Abnormal
1 XXXX −X XX % 0 Normal
2 XXXX −X XX % 0 Normal
3 XXXX −X XX % 0 Normal
4 XXXX 0 XX % 0 Normal
... ... ... ... ... ...

Lifetime statistics

Metric Value Notes
BMS-reported SOH XX % 0 % = pack declared end-of-life by its own BMS
SOH-abnormal events accumulated XXX progressive degradation indicator
Real charge cycles XXX the meaningful real-cycle metric (CYCLE Times)
Charge transitions XXXX NOT real cycles — partial-event counter (Charge Times)
Cell over-voltage trips (BOV) X
Cell low-voltage warnings (BLV) XX
Pack shutdowns X
BMS resets X

Most recent stored event

  • Item Index: XX
  • Time: YYYY-MM-DD HH:MM:SS
  • Voltage: XXXXX mV
  • Current: -XXXX mA
  • Percent: XX %
  • Bat Events: Cell low-voltage warning (cell N)

Raw BMS captures

Raw command output, straight from the BMS, for full traceability:

info

@
info N

  Manufacturer    : Pylon
  Device name     : US3000C
  Board version   : EX0XX-EX0XX-EX-EX
  Main soft version: V1.x
  Soft  version   : V2.x
  Boot  version   : V1.x
  Comm version    : V2.x
  Release date    : YY-MM-DD
  Barcode         : EXAMPLE-FICTIONAL-SERIAL
  Specification   : 48V/74Ah
  Cell number     : 15
  Address         : N

Command completed successfully
$$

(further raw captures truncated for sample — real reports include verbatim pwr, bat, soh, stat and data event output for full traceability)


Generated by pylontech-battery-health. All BMS counters and statuses in a real report are authoritative from the pack's own BMS hardware; no third-party measurement is used.