Repository navigation
Expand file tree
/
Copy pathcapstone.html
More file actions
361 lines (361 loc) · 13.1 KB
/
Copy pathcapstone.html
File metadata and controls
361 lines (361 loc) · 13.1 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
<!doctype html>
<html lang="en">
<head>
<meta charset="utf-8" />
<meta name="viewport" content="width=device-width,initial-scale=1" />
<title>SMA Claw | Stephen Jones</title>
<meta
name="description"
content="Stephen Jones: robotics and mechatronics engineer. Georgia Tech BSME, OMSCS (Computational Perception and Robotics)."
/>
<meta property="og:type" content="website" />
<meta property="og:title" content="Stephen Jones | Robotics Engineer" />
<meta name="theme-color" content="#7ec8f0" />
<link rel="icon" href="assets/opt/headshot.jpeg" />
<link rel="stylesheet" href="style.css" />
</head>
<body data-bg="bird">
<main>
<section class="panel" data-bg="bird">
<h1>Project C.L.A.W.S.: a zero-power perching claw</h1>
<div class="facts">
<div><small>Client</small><b>Khanjur R&D</b></div>
<div><small>Course</small><b>ME 4723, Georgia Tech</b></div>
<div><small>Team</small><b>6 students</b></div>
<div>
<small>My role</small><b>Project Manager and Mechanical Lead</b>
</div>
</div>
<p class="lead">
Small drones fly about 30 minutes, mostly because hovering burns
power. This claw lets a quadcopter grab a railing or pipe and hold on
with 0.0 W, then release on command using shape memory alloy (SMA,
Nitinol) actuators instead of heavy servos.
</p>
<div class="chips">
<span class="chip"><b>0.0 W</b> hold power</span
><span class="chip"><b>8</b> SMA serpentines</span
><span class="chip"><b><150 g</b> target</span
><span class="chip"><b>20-60 mm</b> pipes</span>
</div>
<div class="callout warn">
NDA: proprietary alloy specifications and client CAD are omitted.
Numbers below are from our own bench tests.
</div>
</section>
<section class="panel" data-bg="bird">
<h2>
<svg class="ico" aria-hidden="true"><use href="#i-film" /></svg
>Actuation videos
</h2>
<div class="vids">
<figure>
<video
controls
preload="metadata"
poster="assets/opt/claw-poster.jpg"
>
<source
src="assets/Capstone/Claw_Actuation_Video_Completed.mp4"
type="video/mp4"
/>
</video>
<figcaption>The black working prototype in action.</figcaption>
</figure>
<figure>
<video controls preload="metadata">
<source
src="assets/Capstone/finalprotomanualactuationvid.mp4#t=0.1"
type="video/mp4"
/>
</video>
<figcaption>
Manual actuation of the final prototype: the ratchet locks the
grip with no power.
</figcaption>
</figure>
</div>
</section>
<section class="panel" data-bg="bird">
<h2>Shape memory in action</h2>
<div class="gifbox">
<img
src="assets/Capstone/WTF_Paperclip_Nitinol.gif"
alt="A Nitinol paperclip returning to its shape"
loading="lazy"
decoding="async"
/>
</div>
<p>
Nitinol remembers a shape and snaps back to it when heated. That is
the effect the claw uses to release its ratchet.
</p>
</section>
<section class="panel" data-bg="bird">
<h2>Two prototypes</h2>
<div class="figs" data-car data-label="Capstone prototype photos">
<figure>
<div class="fi">
<img
decoding="async"
src="assets/web/cap-open.jpg"
alt="Blue expo prototype: shows the interior at the expo, shown without Nitinol because of the NDA."
loading="lazy"
/>
</div>
<figcaption>
Blue expo prototype: shows the interior at the expo, shown without
Nitinol because of the NDA.
</figcaption>
</figure>
<figure>
<div class="fi">
<img
decoding="async"
src="assets/web/cap-closeup.jpg"
alt="Close-up of the interior and ratchet hardware."
loading="lazy"
/>
</div>
<figcaption>
Close-up of the interior and ratchet hardware.
</figcaption>
</figure>
<figure>
<div class="fi">
<img
decoding="async"
src="assets/web/cap-expo.jpg"
alt="Presenting at the engineering expo."
loading="lazy"
/>
</div>
<figcaption>Presenting at the engineering expo.</figcaption>
</figure>
</div>
<p>
We built two designs. The <b>blue prototype</b> exposed the inside of
the device for the expo and ran without Nitinol because of the NDA.
The <b>black prototype</b> was the working version shown in the video.
</p>
</section>
<section class="panel" data-bg="sky">
<h2>
<svg class="ico" aria-hidden="true"><use href="#i-box" /></svg
>Interactive assembly render
</h2>
<p>
Drag to rotate and scroll to zoom. This is the assembly with the lid,
Nitinol, electronics, and Kevlar cord removed, so the inside of the
mechanism is visible.
</p>
<div class="render">
<button class="gel blue" data-load>
Load the 3D render (about 9 MB)</button
><iframe
title="3D render of the claw assembly with the top removed"
data-src="assets/Capstone/Project_Assembly_No_Top.html"
allowfullscreen
hidden
></iframe>
</div>
<p>
<a
href="assets/Capstone/Project_Assembly_No_Top.html"
target="_blank"
rel="noopener"
>Open the render in its own tab</a
>
</p>
</section>
<section class="panel" data-bg="sky">
<h2>
<svg class="ico" aria-hidden="true"><use href="#i-waves" /></svg
>Design evolution: four pivots
</h2>
<ol class="steps">
<li>
<b>Reverse-scissor linkage</b> won our weighted decision matrix (196
of 280, ranked 1st). Early prints showed multiple bearing pivots
created parasitic friction, and the rigid jaws could not adapt to
branches. We dropped it.
</li>
<li>
<b>Prototype A: pre-stressed TPU claw.</b> A curled TPU band closes
by default, so power loss means a safe grip. Kevlar tendons open it.
It needed <b>5.8 N</b> to open one claw and held pipes
<b>25-100 mm</b>. It failed above 100 mm, and above a 45 degree
perch angle with more than <b>1.13 kg (11.1 N)</b> the payload
rolled off.
</li>
<li>
<b>Fix: rigid inverted V legs</b> with grip tape and protruding bolt
talons moved overturning loads into a rigid frame.
</li>
<li>
<b>Final: dual ratchet lever arm</b> on a 1/4 inch 6061 hex shaft,
laser-cut acrylic ratchet gears, and holding pawls. SMA only
releases the pawls, so holding costs no power.
</li>
</ol>
<div
class="figs"
data-car="small"
data-label="Early prototype iterations"
>
<figure>
<div class="fi">
<img
src="assets/Capstone/proto1wholeinterior.png"
alt="Whole interior of the first prototype"
loading="lazy"
decoding="async"
/>
</div>
<figcaption>Whole interior of the first prototype</figcaption>
</figure>
<figure>
<div class="fi">
<img
src="assets/Capstone/proto1interiorratchetmechanism.png"
alt="Ratchet mechanism installed in the box"
loading="lazy"
decoding="async"
/>
</div>
<figcaption>Ratchet mechanism installed in the box</figcaption>
</figure>
<figure>
<div class="fi">
<img
src="assets/Capstone/proto1justratchetmechanism.png"
alt="The ratchet mechanism on its own"
loading="lazy"
decoding="async"
/>
</div>
<figcaption>The ratchet mechanism on its own</figcaption>
</figure>
<figure>
<div class="fi">
<img
src="assets/Capstone/proto1pvcforwards.png"
alt="PVC bench rig, front view"
loading="lazy"
decoding="async"
/>
</div>
<figcaption>PVC bench rig, front view</figcaption>
</figure>
<figure>
<div class="fi">
<img
src="assets/Capstone/proto1pvcsideways.png"
alt="PVC bench rig, side view"
loading="lazy"
decoding="async"
/>
</div>
<figcaption>PVC bench rig, side view</figcaption>
</figure>
<figure>
<div class="fi">
<img
src="assets/Capstone/proto1suspended.png"
alt="Rig suspended to test the hold"
loading="lazy"
decoding="async"
/>
</div>
<figcaption>Rig suspended to test the hold</figcaption>
</figure>
<figure>
<div class="fi">
<img
src="assets/Capstone/proto1upsidedown.png"
alt="Rig upside down to test the hold"
loading="lazy"
decoding="async"
/>
</div>
<figcaption>Rig upside down to test the hold</figcaption>
</figure>
</div>
</section>
<section class="panel" data-bg="sky">
<h2>Test data: SMA behavior</h2>
<table>
<thead>
<tr>
<th>Current setting</th>
<th>Result</th>
</tr>
</thead>
<tbody>
<tr>
<th>1.5 A, 1.04 V</th>
<td>Under-actuation, incomplete displacement</td>
</tr>
<tr>
<th>2.0 A, 1.36 V (about 2.7 W)</th>
<td>Nominal: reliably lifted 170 g (1.76 N)</td>
</tr>
<tr>
<th>2.25 A, 1.59 V (about 3.6 W)</th>
<td>Failure: overheated, permanent deformation</td>
</tr>
</tbody>
</table>
<p>
Power vs. actuation speed was linear, and 3.6 W was the upper limit
before this geometry lost its shape memory. We sized power for the
array: 12.0 A at 1.36 V is 16.32 W peak, 489.6 J per perch-and-takeoff
cycle, 7,344 J per hour at 15 cycles, so an 8,000 J battery target.
</p>
</section>
<section class="panel" data-bg="bird">
<h2>Constraints I designed around</h2>
<ul>
<li>
<b>Strain limit:</b> SMA recovers only about 4%, but opening the
claw needed a 5.08 cm tendon stroke, so the actuator needs large
mechanical amplification (bow actuator or bell-crank).
</li>
<li>
<b>Slow cooling</b> sets cycle time, so the claw defaults closed and
SMA only releases.
</li>
<li>
<b>Heat:</b> SMA runs near 90 C, so mounts use heat-resistant tape
and vented housings.
</li>
<li>
<b>Modularity:</b> a 1/4 inch grid of 4-40 screw holes lets pawl
mounts, bearings, and SMA anchors move without new machining.
</li>
</ul>
<div class="callout warn">
<b>What failed:</b> in report-stage bench testing, 15 V at 7 A (over
100 W) still could not overcome sliding friction between the PETG
lever arms and the aluminum shaft. The planned fix was flanged ball
bearings or PTFE sleeves.
</div>
</section>
<section class="panel" data-bg="bird">
<h2>My contributions</h2>
<p>
I led planning and sponsor communication, built the specification
sheet and weighted decision matrix, designed the mounting, linkage,
and actuation options for the morphological chart, and wrote and built
Prototype A.
</p>
</section>
<section class="panel pager">
<a class="gel blue" href="index.html">Previous</a
><a class="gel blue" href="index.html#projects">All projects</a
><a class="gel blue" href="drone.html">Next</a>
</section>
</main>