feat: Add pv_ac_limit for AC coupled inverter PV clipping
Adds a new pv_ac_limit config setting that allows users with AC-coupled
inverters (non-hybrid) to model clipping from their PV system (e.g.,
microinverters with an AC output limit).
- config.py: Add pv_ac_limit to APPS_SCHEMA as a float
- fetch.py: Read pv_ac_limit (in Watts) and store as kWh/min on self
- predbat.py: Initialize self.pv_ac_limit = 0
- prediction.py: Pass pv_ac_limit through and apply AC clipping in
the non-hybrid (else) branch after inverter_limit handling
- tests/test_infra.py: Add pv_ac_limit parameter to simple_scenario
and reset_inverter
- tests/test_model.py: Add four new test scenarios for pv_ac_limit
- docs/apps-yaml.md: Document the new pv_ac_limit setting
Agent-Logs-Url: https://github.com/springfall2008/batpred/sessions/c2b66364-9d11-4c05-8b9f-88095c31c6dd
Co-authored-by: springfall2008 <48591903+springfall2008@users.noreply.github.com>
Copy file name to clipboardExpand all lines: docs/apps-yaml.md
+22Lines changed: 22 additions & 0 deletions
Display the source diff
Display the rich diff
Original file line number
Diff line number
Diff line change
@@ -913,6 +913,28 @@ If you have multiple inverters then set the value of each one in a list format.
913
913
914
914
NB: inverter_limit is ONLY used by Predbat to improve the quality of the plan, any solar clipping is done by the inverter and is not controlled by Predbat.
915
915
916
+
### **pv_ac_limit**
917
+
918
+
Optional, applies to **non-hybrid (AC coupled) inverters only**.
919
+
920
+
Controls the way Predbat models the maximum AC output of your PV system.
921
+
This does not change the way the inverter is controlled.
922
+
923
+
When set, defines the maximum AC output power in watts for your PV system (e.g. microinverters).
924
+
This is used by Predbat to model clipping that occurs when your PV generation exceeds the AC output limit,
925
+
for example if you have microinverters with a rated maximum AC output.
926
+
927
+
This setting is ignored for hybrid inverters (`inverter_hybrid: true`) because in a hybrid system the PV
928
+
connects directly to the DC bus and clipping is already modelled via `inverter_limit`.