- compare.py runs (save=False): the rates read the saved cancellation while the
slots followed a decision made fresh in that run. So a car that had started or
stopped charging since the last live cycle was priced one way and planned the
other. The check now records this run's decision in dynamic_load_car_effective,
and rate_add_io_slots() and the feed strip read that instead.
- An install with no load history (load_forecast only, where load_last_period is
hard-coded to 0) counted as low load, so with car_energy_reported_load on every
dispatch was cancelled 10 minutes in. No load data is now no evidence.
- An unknown/unavailable reading left the grace timer running, so off ->
unavailable -> off cancelled without a fresh grace. No evidence now restarts it.
- A cancelled slot kept its cost. The cost is now zeroed, and publish_car_plan()
includes kwh_cancelled in the planned attribute, so the entity attributes say
why kWh is 0.
- The "will never be trusted" warning now lists only cars with an
octopus_intelligent_slot of their own, not every car without a sensor.
- The feed strip re-strips the same minutes every cycle. It now logs only when
the number stripped changes.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
self.log("Warn: octopus_intelligent_trust_slots is Off but car(s) {} have no car_charging_now sensor and are outside the CT clamp, so their Intelligent slots will never be trusted".format(cars))
# An unknown stretch is no evidence either way: the car may have been charging through it, so a
185
+
# "not charging" reading after it starts a fresh grace period rather than resuming the old one
186
+
print("Test 4c: an unavailable reading restarts the grace clock")
187
+
_reset(my_predbat)
188
+
_sensor(my_predbat, "off")
189
+
_cycle(my_predbat, 840)
190
+
_sensor(my_predbat, "unavailable")
191
+
_cycle(my_predbat, 841)
192
+
_sensor(my_predbat, "off")
193
+
changed=_cycle(my_predbat, 842, 30)
194
+
failed|=_check("t4c not cancelled on the old sighting", (notchanged) and_kwh(my_predbat) == [3.5, 3.5], "changed {} kwh {}".format(changed, _kwh(my_predbat)))
195
+
changed=_cycle(my_predbat, 844, 30)
196
+
failed|=_check("t4c cancelled after a fresh grace", changedand_kwh(my_predbat) == [0, 0], "changed {} kwh {}".format(changed, _kwh(my_predbat)))
197
+
179
198
# A static literal is not a sensor, and without the CT clamp there is no load evidence either
180
199
# A configured entity HA does not have (deleted, renamed, integration reloading) resolves to the
181
200
# read's default - that must be no evidence, not a "not charging" reading (#5229 review)
@@ -212,6 +231,18 @@ def _run(my_predbat):
212
231
changed=_cycle(my_predbat, 855)
213
232
failed|=_check("t6 load back up resumes", changedand_kwh(my_predbat) == [3.5, 3.5], "changed {} kwh {}".format(changed, _kwh(my_predbat)))
214
233
234
+
# A load_forecast-only install has no load_today history and a hard-coded load_last_period of 0,
235
+
# which is not evidence of anything (#5229 review)
236
+
print("Test 6c: no load history is not low-load evidence")
0 commit comments