docs(sigenergy): fix rate automation sensor names, re-apply mode on restart, stop zeroing import limit in freeze (#5464)
* docs(sigenergy): fix rate automation sensor names, re-apply mode on restart, stop zeroing import limit in freeze (#5459)
- Rate automations: cap against the plant-level
sensor.sigen_plant_ess_rated_charging/discharging_power (what the
template's battery_rate_max already uses, and what matches the
plant-level limits being written). The inverter prefix with "-ing"
suffix used here doesn't exist in the integration. Skip the write if
the rate input isn't a number (rather than writing 0kW), and treat an
unavailable rated-power sensor as no cap.
- Rework the renamed-entities note around the plant/inverter split, and
warn that renaming charge_rate/discharge_rate in apps.yaml but not in
the automations silently stops them firing.
- Restarts: drop initial: from the three helpers so HA restores them
instead of resetting them without a state change, and re-apply the
mode on HA start and when Remote EMS goes from off to on. A restart at
the end of a force export otherwise left the plant on Command
Discharging while Predbat already wanted Demand and wrote nothing.
Wait for the select and SoC sensor before writing, and make the Freeze
Charging pin fall back to 0, not 100: a re-run with SoC unreadable
would otherwise pin the cut-off at 99.75% and trigger the documented
forced-import firmware bug.
- Stop setting grid_import_limitation to 0 in both freeze modes (#4911):
the cut-offs enforce the freeze, 0 contradicts Freeze Charging's own
definition, and it stalls Sigenergy EV chargers behind the plant CT.
Tell existing users to reset it once.
- Say that Remote EMS must be on, fix the enable-list entry to the
daily_load_consumption name the template uses, and add an optional
Remote EMS watchdog.
All of this is running on a live Sigenergy system: the import-limit
change since 9 Sep, the rest since 9 Oct.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
* docs(sigenergy): correct enable list and battery_rate_max claim (#5459)
The enable list named sensor.sigen_plant_max_active_power, which the
integration enables by default; the template's inverter_limit uses
sensor.sigen_plant_available_max_active_power, which is disabled by
default. The rate-automation note also said battery_rate_max uses both
plant rated-power sensors; it uses only the discharging one.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
* docs(sigenergy): re-apply rate limits after restart or Remote EMS re-enable (#5459)
The rate automations fired only when the input number changed. Now that
the helpers restore their state across a restart, a limit write lost to a
restart or an integration outage was never retried: Predbat saw the input
number already at the value it wanted. Both rate automations now also
trigger on Home Assistant start and on Remote EMS going from off to on,
wait for the plant limit entity before writing, and run in restart mode so
the latest rate wins. The condition reads the input number directly, as
trigger.to_state does not exist for the new triggers.
Also tell new users to set the rate helpers once, as without initial: they
start at 0 W, which Predbat reads as the battery being held.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
* docs(sigenergy): don't re-apply a 0 W rate on restart, and correct what the re-apply covers (#5459)
On a new install the rate input numbers start at 0 W, so the new Home
Assistant start trigger would write a 0 kW charge and discharge limit to
the plant on the first restart, blocking the battery. The re-apply
triggers now skip a 0 W rate; a real rate change still writes 0.
The comment also claimed the triggers retry a write lost to an
integration outage, which they don't (recovery is unavailable to
available, which nothing triggers on). It now names what they do cover:
a write lost to a restart, and a limit changed by another service while
Remote EMS was off.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
* docs(sigenergy): re-apply 0 W holds after a restart again (#5459)
The previous commit skipped a 0 W rate on the re-apply triggers to spare
new installs a 0 kW limit on their first restart. That also stopped a lost
or overwritten hold (Predbat's deliberate rate 0) from being put back,
which is the main case the triggers exist for: Predbat only writes the
rate when it reads a different value, so it never re-sends a hold it
already sees. A new install needs no special case, because Predbat writes
its non-zero rate on its first cycle. Drop the guard and say in the
new-install note that the restart writes the 0 W default to the plant.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
* docs(sigenergy): correct the rate guard rationale and the Axle watchdog condition (#5459)
The rate automation comments said the is_number condition and the
float(99) fallback avoid writing a 0 kW limit. In current Home Assistant
'| float' with no default raises on 'unavailable', so the old behaviour
was a template error and no write; the comments now say so.
The watchdog's optional Axle condition only works with Predbat's own Axle
integration enabled, under the configured prefix (axle.py builds the
entity as binary_sensor.<prefix>_axle_event). Without it the condition
never passes and the watchdog never runs; the comment now says this.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
---------
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
@@ -1885,15 +1885,22 @@ To integrate your Sigenergy Sigenstor inverter with Predbat, you will need to fo
1885
1885
- All the Sigenergy entities referenced in `apps.yaml` need to be enabled for Predbat to use them. The following are disabled by default and will need enabling:
- The following additions are needed to facilitate integration with Predbat and need to be put into Home Assistant's `configuration.yaml` or configured via the HA user interface:
1896
+
- Turn on **switch.sigen_plant_remote_ems_controlled_by_home_assistant** ("Remote EMS (Controlled by Home Assistant)"). While it is off the plant ignores **select.sigen_plant_remote_ems_control_mode** entirely and runs its own logic,
1897
+
so none of the mode changes made by the automations below take effect. The cut-off and limit numbers are still obeyed without it, which can make a setup look partly working.
1898
+
1899
+
- The following additions are needed to facilitate integration with Predbat and need to be put into Home Assistant's `configuration.yaml` or configured via the HA user interface.
1900
+
They deliberately have no `initial:` value, so Home Assistant restores their last state on a restart. With `initial:` they are reset on every restart without a state change,
1901
+
so the automations below don't fire and the plant can be left in a mode, or at a rate limit, that no longer matches what Predbat sees.
1902
+
Without `initial:`, a new **input_number.charge_rate** / **input_number.discharge_rate** starts at 0 W, which Predbat reads as the battery being held, and which the rate automations below write to the plant on a restart.
1903
+
On a new install, set each once to your plant's rated charging / discharging power in W.
1897
1904
1898
1905
```yaml
1899
1906
input_select:
@@ -1905,13 +1912,11 @@ input_select:
1905
1912
- "Freeze Charging"
1906
1913
- "Discharging"
1907
1914
- "Freeze Discharging"
1908
-
initial: "Demand"
1909
1915
icon: mdi:battery-unknown
1910
1916
1911
1917
input_number:
1912
1918
charge_rate:
1913
1919
name: Battery charge rate
1914
-
initial: 6950
1915
1920
min: 0
1916
1921
max: 20000
1917
1922
step: 1
@@ -1920,7 +1925,6 @@ input_number:
1920
1925
1921
1926
discharge_rate:
1922
1927
name: Battery discharge rate
1923
-
initial: 8000
1924
1928
min: 0
1925
1929
max: 20000
1926
1930
step: 1
@@ -1939,8 +1943,26 @@ Add the following automations to `automations.yaml` (or configure via the UI):
1939
1943
- trigger: state
1940
1944
entity_id:
1941
1945
- input_select.predbat_requested_mode
1946
+
# Re-apply the mode after a Home Assistant restart, and when Remote EMS is switched back on (by you,
1947
+
# or after another service turned it off), as the plant may be in a different mode by then.
1948
+
# Without the restart trigger, a restart at the end of a force export can leave the plant on
1949
+
# "Command Discharging" if Predbat already wants "Demand": Predbat sees nothing to change, writes
1950
+
# nothing, and the battery keeps exporting past its target.
*Note:* Some Sigenergy Predbat users have reported that their Sigenergy modbus integration has created some of the entities that Predbat requires with different names
2092
-
so you may need to adapt the above automations and `apps.yaml` (or rename your entities) to match:
2141
+
*Note:* The rate automations cap the requested rate at the **plant**-level rated power, **sensor.sigen_plant_ess_rated_charging_power** and **sensor.sigen_plant_ess_rated_discharging_power**,
2142
+
which match the plant-level limits being written (the template's `battery_rate_max` uses the same plant-level discharging sensor). Per-inverter versions, where your integration creates them, are named without the "-ing"
2143
+
(e.g. sensor.sigen_inverter_ess_rated_charge_power); earlier versions of this page mixed the two spellings, giving entity names that don't exist.
2144
+
Make sure both are enabled: if one is missing or disabled the automation runs without a cap. If you don't have sensor.sigen_plant_daily_load_consumption,
2145
+
look for sensor.sigen_plant_daily_consumed_energy (the name earlier versions of this page used) and use that in `apps.yaml` instead.
2093
2146
2094
-
- sensor.sigen_inverter_ess_rated_discharging_power is instead named sensor.sigen_inverter_ess_rated_discharge_power
2095
-
- sensor.sigen_inverter_ess_rated_charging_power is sensor.sigen_inverter_ess_rated_charge_power
2096
-
- sensor.sigen_plant_daily_consumed_energy is sensor.sigen_plant_daily_load_consumption
2147
+
*Note:* If you rename **input_number.charge_rate** / **input_number.discharge_rate**, change them in `apps.yaml` **and** in the triggers and templates of the rate automations.
2148
+
If the two disagree the automations never fire, and nothing reports it: the plant simply stays at whatever limit it last had, so Predbat's rate changes (including setting a rate of 0 to hold the battery) never reach the inverter.
2097
2149
2098
-
*Important:* Depending upon your electricity supply, you may need to change where **number.sigen_plant_grid_import_limitation** is set to 100 in the first integration to any lower import limit that your electricity supplier may have imposed,
2150
+
*Important:* Depending upon your electricity supply, you may need to change where **number.sigen_plant_grid_import_limitation** is set to 100 in the first automation to any lower import limit that your electricity supplier may have imposed,
2099
2151
e.g. 18kW roughly corresponds to an 80A supply.
2100
2152
2101
-
*Important:* Sigenergy have confirmed this is a known firmware bug on their side (not a Predbat or integration issue): even with **grid_import_limitation** set to 0kW, the inverter will still import from the grid to charge the battery if the current SoC is below **discharge_cut_off_state_of_charge**. In practice this has been observed importing several kW, not just a trickle, when the gap between SoC and the cut-off is large - continuing unattended until the target is reached. **grid_import_limitation** is therefore not a reliable backstop against this: the fix is keeping **discharge_cut_off_state_of_charge** pinned so it's never above current SoC, as the automation above does.
2153
+
*Important:* Earlier versions of this page set **grid_import_limitation** to 0 in both freeze modes. That is no longer recommended (see [batpred#4911](https://github.com/springfall2008/batpred/issues/4911)): the freeze is
2154
+
enforced by the charge and discharge cut-offs, not by the import limit, and a 0kW import limit contradicts Freeze Charging's own definition (house load beyond solar is met from the grid).
2155
+
It also stalls a Sigenergy EV charger (EVAC/EVDC) behind the plant's CT clamp, which the plant throttles to the import limit - and one of the times Predbat uses Freeze Charging is to hold the battery while the car charges.
2156
+
If you are updating from the older automation, set **number.sigen_plant_grid_import_limitation** back to your supply limit once, as a freeze mode may have left it at 0.
2157
+
2158
+
*Important:* Sigenergy have confirmed this is a known firmware bug on their side (not a Predbat or integration issue): even if **grid_import_limitation** is set to 0kW, the inverter will still import from the grid to charge the battery if the current SoC is below **discharge_cut_off_state_of_charge**. In practice this has been observed importing several kW, not just a trickle, when the gap between SoC and the cut-off is large - continuing unattended until the target is reached. **grid_import_limitation** is therefore not a reliable backstop against this: the fix is keeping **discharge_cut_off_state_of_charge** pinned so it's never above current SoC, as the automation above does.
2102
2159
2103
-
The pin is set once, when Freeze Charging starts, rather than continuously updated as SoC changes - and this matters, not just as a simplification. "Frozen" means holding a fixed point; if the target itself kept moving to track live SoC, any downward drift (from real losses or otherwise) would just relocate the target to wherever the battery ended up, with nothing ever correcting it back. A fixed target is what makes the correction mechanism (the same import behaviour that caused the original bug) actually useful: it holds the line against any real deficit, including the inverter's own standby losses, not just customer load. The small margin (0.25 percentage points) below the pinned value exists to cover possible imprecision in that one reading - not ongoing noise tolerance, since the pin is fixed rather than re-sampled, so only the single initial reading matters. It still matters because the underlying mechanism only ever corrects one way: a reading that's a hair low at the moment of pinning would cost a real, if tiny, import to "correct" a gap that was never really there, while a reading that's a hair high costs nothing - so even a one-off imprecise read isn't self-cancelling without some margin.
2160
+
The pin is set once, when Freeze Charging starts, rather than continuously updated as SoC changes - and this matters, not just as a simplification. "Frozen" means holding a fixed point; if the target itself kept moving to track live SoC, any downward drift (from real losses or otherwise) would just relocate the target to wherever the battery ended up, with nothing ever correcting it back. A fixed target is what makes the correction mechanism (the same import behaviour that caused the original bug) actually useful: it holds the line against any real deficit, including the inverter's own standby losses, not just customer load. The small margin (0.25 percentage points) below the pinned value exists to cover possible imprecision in that one reading - not ongoing noise tolerance, since the pin is fixed rather than re-sampled, so only the single initial reading matters. (The pin is also re-taken if the automation re-runs during Freeze Charging - after a Home Assistant restart, or when Remote EMS is switched back on - which is a rare, one-off reset rather than continuous tracking.) It still matters because the underlying mechanism only ever corrects one way: a reading that's a hair low at the moment of pinning would cost a real, if tiny, import to "correct" a gap that was never really there, while a reading that's a hair high costs nothing - so even a one-off imprecise read isn't self-cancelling without some margin.
2104
2161
2105
2162
The margin is clamped at 0 (`[value, 0] | max`) rather than allowed to go negative. This isn't just tidiness: `discharge_cut_off_state_of_charge`is an unsigned 16-bit Modbus register on the wire, and the integration's own write encoding has no guard against a negative value - it would silently wrap around into a huge, nonsensical raw value rather than being rejected. At very low SoC (below the margin) an unclamped template could produce exactly that.
2106
2163
2107
2164
See [batpred#4375](https://github.com/springfall2008/batpred/issues/4375) and the wider [Sigenergy setup discussion](https://github.com/springfall2008/batpred/issues/2077) for the full investigation, including a more advanced (currently experimental, untested) variant that ratchets the target up in response to confirmed solar surplus over each period rather than using a fixed one-off value.
2108
2165
2166
+
*Optional:* other services that control the plant can turn **switch.sigen_plant_remote_ems_controlled_by_home_assistant** off and not turn it back on. On one user's system this happened after an Axle VPP event,
2167
+
and again after connecting a cloud service to the Sigenergy account, with nothing in Home Assistant recording why. While it is off the plant ignores Predbat's mode changes (on that occasion for 7 hours,
2168
+
running the battery empty overnight). This watchdog notifies you and turns it back on, and the mode and rate automations above then re-apply Predbat's current mode and limits.
2169
+
Note that it will also undo a deliberate switch-off - disable the watchdog first if you want Remote EMS off for a while.
2170
+
2171
+
```yaml
2172
+
- id: predbat_sigenergy_remote_ems_watchdog
2173
+
alias: "Predbat Sigenergy Remote EMS Watchdog"
2174
+
description: "Turn Remote EMS back on if something else has turned it off"
0 commit comments