Skip to content

Commit f196191

Browse files
authored
Map Sigenergy ESS max discharge limit to battery rate max
Previously the battery_rate_max value was simply mapped from the plant max power, but this fails to account for the discharge rate limit of the installed batteries (for example, in a single battery system the max battery discharge rate is ~4.8kw).
1 parent 7ae4318 commit f196191

1 file changed

Lines changed: 1 addition & 1 deletion

File tree

‎templates/sigenergy_sigenstor.yaml‎

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -103,7 +103,7 @@ pred_bat:
103103

104104
# Set the maximum charge/discharge rate of the battery
105105
battery_rate_max:
106-
- sensor.sigen_plant_available_max_active_power
106+
- sensor.sigen_plant_ess_rated_discharging_power
107107

108108
# Export limit is a software limit set on your inverter that prevents exporting above a given level
109109
# When enabled Predbat will model this limit

0 commit comments