136 changes: 136 additions & 0 deletions apps/predbat/config.py
Original file line number Diff line number Diff line change
Expand Up @@ -322,6 +322,58 @@
"enable": "num_cars",
"enable_condition": "num_cars > 3",
},
{
"name": "car_charging_rate_4",
"friendly_name": "Car charging rate (Car 4)",
"type": "input_number",
"min": 1,
"max": 24,
"step": 0.10,
"unit": "kW",
"icon": "mdi:ev-station",
"default": 7.4,
"enable": "num_cars",
"enable_condition": "num_cars > 4",
},
{
"name": "car_charging_rate_5",
"friendly_name": "Car charging rate (Car 5)",
"type": "input_number",
"min": 1,
"max": 24,
"step": 0.10,
"unit": "kW",
"icon": "mdi:ev-station",
"default": 7.4,
"enable": "num_cars",
"enable_condition": "num_cars > 5",
},
{
"name": "car_charging_rate_6",
"friendly_name": "Car charging rate (Car 6)",
"type": "input_number",
"min": 1,
"max": 24,
"step": 0.10,
"unit": "kW",
"icon": "mdi:ev-station",
"default": 7.4,
"enable": "num_cars",
"enable_condition": "num_cars > 6",
},
{
"name": "car_charging_rate_7",
"friendly_name": "Car charging rate (Car 7)",
"type": "input_number",
"min": 1,
"max": 24,
"step": 0.10,
"unit": "kW",
"icon": "mdi:ev-station",
"default": 7.4,
"enable": "num_cars",
"enable_condition": "num_cars > 7",
},
{
"name": "car_charging_loss",
"friendly_name": "Car charging loss",
Expand Down Expand Up @@ -741,6 +793,90 @@
"default": 0.0,
"restore": False,
},
{
"name": "car_charging_manual_soc_4",
"friendly_name": "Car charging manual SOC (Car 4)",
"type": "switch",
"default": False,
"enable": "num_cars",
"enable_condition": "num_cars > 4",
},
{
"name": "car_charging_manual_soc_kwh_4",
"friendly_name": "Car manual SOC kWh (Car 4)",
"type": "input_number",
"min": 0,
"max": 100,
"step": 0.01,
"unit": "kWh",
"icon": "mdi:ev-station",
"enable": "car_charging_manual_soc_4",
"default": 0.0,
"restore": False,
},
{
"name": "car_charging_manual_soc_5",
"friendly_name": "Car charging manual SOC (Car 5)",
"type": "switch",
"default": False,
"enable": "num_cars",
"enable_condition": "num_cars > 5",
},
{
"name": "car_charging_manual_soc_kwh_5",
"friendly_name": "Car manual SOC kWh (Car 5)",
"type": "input_number",
"min": 0,
"max": 100,
"step": 0.01,
"unit": "kWh",
"icon": "mdi:ev-station",
"enable": "car_charging_manual_soc_5",
"default": 0.0,
"restore": False,
},
{
"name": "car_charging_manual_soc_6",
"friendly_name": "Car charging manual SOC (Car 6)",
"type": "switch",
"default": False,
"enable": "num_cars",
"enable_condition": "num_cars > 6",
},
{
"name": "car_charging_manual_soc_kwh_6",
"friendly_name": "Car manual SOC kWh (Car 6)",
"type": "input_number",
"min": 0,
"max": 100,
"step": 0.01,
"unit": "kWh",
"icon": "mdi:ev-station",
"enable": "car_charging_manual_soc_6",
"default": 0.0,
"restore": False,
},
{
"name": "car_charging_manual_soc_7",
"friendly_name": "Car charging manual SOC (Car 7)",
"type": "switch",
"default": False,
"enable": "num_cars",
"enable_condition": "num_cars > 7",
},
{
"name": "car_charging_manual_soc_kwh_7",
"friendly_name": "Car manual SOC kWh (Car 7)",
"type": "input_number",
"min": 0,
"max": 100,
"step": 0.01,
"unit": "kWh",
"icon": "mdi:ev-station",
"enable": "car_charging_manual_soc_7",
"default": 0.0,
"restore": False,
},
{
"name": "octopus_intelligent_charging",
"friendly_name": "Octopus Intelligent Charging",
Expand Down
2 changes: 1 addition & 1 deletion apps/predbat/const.py
Original file line number Diff line number Diff line change
Expand Up @@ -40,7 +40,7 @@
INVERTER_MAX_RETRY_REST = 5 # Maximum number of retries for inverter REST commands
INVERTER_REST_TIMEOUT = 10 # Seconds to wait for a REST response before giving up (local network call, should be fast)
INVERTER_QUICK_UPDATE_SECONDS = 120 # Minimum seconds between quick inverter data updates
PREDBAT_MAX_CARS = 4 # Matches PK_MAX_CARS in prediction_kernel.cpp and the car_charging_rate_0..3 config items - the hard ceiling on num_cars
PREDBAT_MAX_CARS = 8 # Matches PK_MAX_CARS in prediction_kernel.cpp and the car_charging_rate/_1../_7 config items - the hard ceiling on num_cars
Comment thread
springfall2008 marked this conversation as resolved.

# 240v x 100 amps x 3 phases / 1000 to kW / 60 minutes in an hour is the maximum kWh in a 1 minute period
MAX_INCREMENT = 240 * 100 * 3 / 1000 / 60
Expand Down
4 changes: 2 additions & 2 deletions apps/predbat/prediction_kernel.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -43,8 +43,8 @@
// falling back. Bumping makes the loader reject it and use the Python engine, which is the whole
// point of the check.
#define PK_ABI_VERSION 4
#define PK_PARITY_REVISION 5
#define PK_MAX_CARS 4
#define PK_PARITY_REVISION 6
#define PK_MAX_CARS 8
#define PK_RUN_EVERY 5 // const.py RUN_EVERY

namespace {
Expand Down
8 changes: 4 additions & 4 deletions apps/predbat/prediction_kernel.py
Original file line number Diff line number Diff line change
Expand Up @@ -32,7 +32,7 @@

# Expected ABI/parity revisions of the shared library (see prediction_kernel.cpp)
KERNEL_ABI_VERSION = 4
KERNEL_PARITY_REVISION = 5
KERNEL_PARITY_REVISION = 6

# Maximum number of cars supported by the kernel (PK_MAX_CARS in prediction_kernel.cpp)
KERNEL_MAX_CARS = PREDBAT_MAX_CARS
Expand Down Expand Up @@ -97,8 +97,8 @@ class PkContext(ctypes.Structure):
("export_today_now", ctypes.c_double),
("iboost_today", ctypes.c_double),
("car_charging_loss", ctypes.c_double),
("car_charging_limit", ctypes.c_double * 4),
("car_charging_soc", ctypes.c_double * 4),
("car_charging_limit", ctypes.c_double * KERNEL_MAX_CARS),
("car_charging_soc", ctypes.c_double * KERNEL_MAX_CARS),
("iboost_max_energy", ctypes.c_double),
("iboost_max_power", ctypes.c_double),
("iboost_min_power", ctypes.c_double),
Expand Down Expand Up @@ -169,7 +169,7 @@ class PkResult(ctypes.Structure):
("metric_keep", ctypes.c_double),
("final_iboost", ctypes.c_double),
("final_carbon_g", ctypes.c_double),
("car_soc_next", ctypes.c_double * 4),
("car_soc_next", ctypes.c_double * KERNEL_MAX_CARS),
("iboost_next", ctypes.c_double),
("soc_min_minute", ctypes.c_int32),
("car_soc_next_valid", ctypes.c_int32),
Expand Down
Binary file modified apps/predbat/prediction_kernel_lib_aarch64.so
Binary file not shown.
Binary file modified apps/predbat/prediction_kernel_lib_armv7l.so
Binary file not shown.
Binary file modified apps/predbat/prediction_kernel_lib_darwin_arm64.so
Binary file not shown.
Binary file modified apps/predbat/prediction_kernel_lib_darwin_x86_64.so
Binary file not shown.
Binary file modified apps/predbat/prediction_kernel_lib_i686.so
Binary file not shown.
Binary file modified apps/predbat/prediction_kernel_lib_x86_64.so
Binary file not shown.
24 changes: 22 additions & 2 deletions apps/predbat/tests/test_fetch_config_options.py
Original file line number Diff line number Diff line change
Expand Up @@ -363,11 +363,11 @@ def mock_expose_config(key, value):
# misconfiguration) must not be allowed through - car indices beyond the supported maximum
# have no HA config entity, which previously crashed get_car_charging_planned() with
# TypeError: float() argument must be a string or a real number, not 'NoneType'.
mock_config.config["num_cars"] = 6
mock_config.config["num_cars"] = 12

my_predbat.fetch_config_options()

assert my_predbat.num_cars == 4, "num_cars should be clamped to 4 (the supported maximum), got {}".format(my_predbat.num_cars)
assert my_predbat.num_cars == 8, "num_cars should be clamped to 8 (the supported maximum), got {}".format(my_predbat.num_cars)

print("✓ num_cars clamp test passed")

Expand All @@ -384,5 +384,25 @@ def mock_expose_config(key, value):
my_predbat.expose_config = original_expose_config
my_predbat.args = original_args

# Test 15: get_car_charging_planned resolves all 8 supported cars against the real
# CONFIG_ITEMS/config_index (not the MockConfigProvider above) - this is the exact code path
# that crashed with TypeError: float() argument must be a string or a real number, not
# 'NoneType' when num_cars exceeded the number of car_charging_rate_N entities defined.
print("\n*** Test 15: get_car_charging_planned resolves all 8 cars via real config_index ***")

original_num_cars = my_predbat.num_cars
my_predbat.num_cars = 8
my_predbat.get_car_charging_planned()

assert len(my_predbat.car_charging_rate) == 8, "car_charging_rate should have 8 entries, got {}".format(len(my_predbat.car_charging_rate))
for car_n, rate in enumerate(my_predbat.car_charging_rate):
assert rate == 7.4, "car {} charging rate should default to 7.4, got {}".format(car_n, rate)

# Restore real config state for any tests that run after this one
my_predbat.num_cars = original_num_cars
my_predbat.fetch_config_options()

print("✓ 8-car config resolution test passed")

print("\n**** All fetch_config_options tests passed! ****")
return False
11 changes: 8 additions & 3 deletions apps/predbat/tests/test_infra.py
Original file line number Diff line number Diff line change
Expand Up @@ -9,6 +9,7 @@
# pylint: disable=attribute-defined-outside-init

from datetime import datetime, timedelta
from const import PREDBAT_MAX_CARS
from prediction import Prediction
from matplotlib import pyplot as plt
import asyncio
Expand Down Expand Up @@ -408,6 +409,10 @@ def get_default_config(self):
"car_charging_rate_1": 7.4,
"car_charging_rate_2": 7.4,
"car_charging_rate_3": 7.4,
"car_charging_rate_4": 7.4,
"car_charging_rate_5": 7.4,
"car_charging_rate_6": 7.4,
"car_charging_rate_7": 7.4,
Comment thread
springfall2008 marked this conversation as resolved.
"car_charging_battery_size_0": 100.0,
"car_charging_battery_size_1": 100.0,
"car_charging_limit_0": 100.0,
Expand Down Expand Up @@ -509,8 +514,8 @@ def reset_inverter(my_predbat):
my_predbat.num_cars = 0
my_predbat.car_charging_slots[0] = []
my_predbat.car_charging_from_battery = True
my_predbat.car_charging_limit = [100.0, 100.0, 100.0, 100.0]
my_predbat.car_charging_soc = [0, 0, 0, 0]
my_predbat.car_charging_limit = [100.0] * PREDBAT_MAX_CARS
my_predbat.car_charging_soc = [0] * PREDBAT_MAX_CARS
my_predbat.iboost_enable = False
my_predbat.iboost_solar = False
my_predbat.iboost_gas = False
Expand All @@ -523,7 +528,7 @@ def reset_inverter(my_predbat):
my_predbat.best_soc_keep = 0.0
my_predbat.carbon_enable = 0
my_predbat.inverter_soc_reset = True
my_predbat.car_charging_soc_next = [None for car_n in range(4)]
my_predbat.car_charging_soc_next = [None for car_n in range(PREDBAT_MAX_CARS)]
my_predbat.charge_limit_best = []
my_predbat.charge_window_best = []
my_predbat.export_limits_best = []
Expand Down
9 changes: 5 additions & 4 deletions apps/predbat/tests/test_octopus_misc.py
Original file line number Diff line number Diff line change
Expand Up @@ -1872,10 +1872,11 @@ def test_octopus_automatic_config_num_cars(my_predbat):
original_args = dict(my_predbat.args)

# Test 1: 5 registered devices, 2 suspended - only the 3 active devices should count towards
# num_cars and appear in the entity lists. Without this filter num_cars would be bumped to 5,
# which exceeds the 4 cars Predbat/the kernel support and previously crashed
# get_car_charging_planned() with TypeError: float() argument must be a string or a real number,
# not 'NoneType' (car_charging_rate_4 has no config entity).
# num_cars and appear in the entity lists. A stale/decommissioned device left in an Octopus
# account should not be treated as a car needing a charging slot (and, before
# fetch_config_options' num_cars clamp existed, an inflated count could push num_cars past
# what Predbat supports and crash get_car_charging_planned() with TypeError: float() argument
# must be a string or a real number, not 'NoneType').
print("\n*** Test 1: Suspended devices are excluded from num_cars and entity lists ***")
api = OctopusAPI(my_predbat, key="test-api-key", account_id="test-account", automatic=False)
api.intelligent_devices = {
Expand Down
Loading