46 changes: 35 additions & 11 deletions apps/predbat/execute.py
Original file line number Diff line number Diff line change
Expand Up @@ -72,6 +72,31 @@ def resolve_multi_inverter_status(status_per_inverter, current_status):
return current_status


def build_status_extra(status_extra_parts):
"""Assemble the per-inverter status detail text recorded during execute_plan().

Each entry is ``(inverter_id, lead, label, detail)``: ``lead`` is the introductory word used by the
first inverter ("target"/"current SoC"), ``label`` is that inverter's own core charge/export state
and ``detail`` the SoC figures.

The per-inverter ``label`` only carries information when the fleet's inverters actually disagree.
#4466 added it so a mixed fleet could be read at all, but emitting it unconditionally repeated the
headline status on every system whose inverters agree - a single-inverter install showed
"Exporting target Exporting 19%-5%". Labels are therefore dropped when every segment carries the
same one, restoring the pre-#4466 text for a single inverter and for any fleet acting in unison,
and kept when they differ.
"""
if not status_extra_parts:
return ""
show_labels = len({label for _, _, label, _ in status_extra_parts}) > 1
status_extra = ""
for inverter_id, lead, label, detail in status_extra_parts:
# Only the first inverter introduces the text; the rest are appended after a separator.
status_extra += " {}".format(lead) if inverter_id == 0 else " /"
status_extra += " {} {}".format(label, detail) if show_labels else " {}".format(detail)
return status_extra


class Execute:
"""Execution mixin for applying optimised plans to physical inverters.

Expand All @@ -81,7 +106,9 @@ class Execute:
"""

def execute_plan(self):
status_extra = "" # extra status text added to Predbat notifications
# Per-inverter detail segments, assembled into the status text after the headline status is
# resolved - see build_status_extra() for why they can't be concatenated inline.
status_extra_parts = []
status_hold_car = "" # car hold status text
status_hold_iboost = "" # iBoost hold status text
status_freeze_export = "" # freeze export during demand status text
Expand Down Expand Up @@ -249,8 +276,7 @@ def execute_plan(self):

status = "Freeze charging"
status_per_inverter[inverter.id] = status
status_extra += " target" if inverter.id == 0 else " /" # Append multi-inverter target SoC's together
status_extra += " {} {}%".format(status, inverter.soc_percent)
status_extra_parts.append((inverter.id, "target", status, "{}%".format(inverter.soc_percent))) # Append multi-inverter target SoC's together
self.log("Inverter {} Freeze charging with SoC {}%".format(inverter.id, inverter.soc_percent))
else:
# We can only hold charge if a) we have a way to hold the charge level on the reserve or with a pause feature
Expand Down Expand Up @@ -295,8 +321,7 @@ def execute_plan(self):
status_per_inverter[inverter.id] = status
inverter.adjust_charge_window(charge_start_time, charge_end_time, self.minutes_now)

status_extra += " target" if inverter.id == 0 else " /" # append multi-inverter target SoC's together
status_extra += " {} {}%-{}%".format(status, inverter.soc_percent, inv_target_soc_percent)
status_extra_parts.append((inverter.id, "target", status, "{}%-{}%".format(inverter.soc_percent, inv_target_soc_percent))) # append multi-inverter target SoC's together

if not self.set_discharge_during_charge and resetPause:
# Do we discharge discharge during charge
Expand Down Expand Up @@ -432,8 +457,7 @@ def execute_plan(self):

status = "Exporting"
status_per_inverter[inverter.id] = status
status_extra += " target" if inverter.id == 0 else " /" # append multi-inverter target SoC's together
status_extra += " {} {}%-{}%".format(status, inverter.soc_percent, int(target))
status_extra_parts.append((inverter.id, "target", status, "{}%-{}%".format(inverter.soc_percent, int(target)))) # append multi-inverter target SoC's together
# Immediate export mode
else:
inverter.adjust_force_export(False)
Expand All @@ -453,17 +477,16 @@ def execute_plan(self):
self.log("Export Freeze as exporting is now at/below target - current SoC {}kWh and target {}kWh".format(self.soc_kw, discharge_soc))
status = "Freeze exporting"
status_per_inverter[inverter.id] = status
status_extra += " current SoC" if inverter.id == 0 else " /" # append multi-inverter target SoC's together
status_extra += " {} {}%".format(status, inverter.soc_percent) # Discharge limit (99) is meaningless when Freeze Exporting so don't display it
# Discharge limit (99) is meaningless when Freeze Exporting so don't display it
status_extra_parts.append((inverter.id, "current SoC", status, "{}%".format(inverter.soc_percent))) # append multi-inverter target SoC's together
isExporting = True
target = self.export_window_best[0].get("target", self.export_limits_best[0])
self.isExporting_Target = int(target)
else:
status = "Hold exporting"
status_per_inverter[inverter.id] = status
target = self.export_window_best[0].get("target", self.export_limits_best[0])
status_extra += " target" if inverter.id == 0 else " /" # append multi-inverter target SoC's together
status_extra += " {} {}%-{}%".format(status, inverter.soc_percent, inverter.soc_percent)
status_extra_parts.append((inverter.id, "target", status, "{}%-{}%".format(inverter.soc_percent, inverter.soc_percent))) # append multi-inverter target SoC's together
self.isExporting_Target = inverter.soc_percent
self.log("Export Hold (Demand mode) as export is now at/below target or freeze only is set - current SoC {}kWh and target {}kWh".format(self.soc_kw, discharge_soc))
else:
Expand Down Expand Up @@ -691,6 +714,7 @@ def execute_plan(self):
# Resolve the headline status across all inverters rather than leaving whichever inverter was
# processed last to silently win.
status = resolve_multi_inverter_status(status_per_inverter, status)
status_extra = build_status_extra(status_extra_parts)

# Set the charge/discharge status information
self.set_charge_export_status(isCharging, isExporting, not (isCharging or isExporting))
Expand Down
2 changes: 1 addition & 1 deletion apps/predbat/predbat.py
Original file line number Diff line number Diff line change
Expand Up @@ -35,7 +35,7 @@
import pytz
import asyncio

THIS_VERSION = "v8.48.5"
THIS_VERSION = "v8.48.6"

from download import predbat_update_move, predbat_update_download, check_install, DEFAULT_PREDBAT_REPOSITORY
from const import MINUTE_WATT
Expand Down
28 changes: 28 additions & 0 deletions apps/predbat/tests/test_execute.py
Original file line number Diff line number Diff line change
Expand Up @@ -2230,6 +2230,8 @@ def run_execute_tests(my_predbat):
set_export_window=True,
soc_kw=100,
assert_status="Exporting",
# A fleet acting in unison must not repeat the headline status on every segment (v8.48.4 regression)
assert_status_extra=" target 100%-0% / 100%-0%",
car_slot=charge_window_best_slot,
car_charging_from_battery=True,
assert_force_export=True,
Expand Down Expand Up @@ -2259,6 +2261,32 @@ def run_execute_tests(my_predbat):
if failed:
return failed

# Single-inverter status text (v8.48.4 regression): every other case in this module runs two
# inverters, so the single-inverter rendering had no end-to-end coverage at all and shipped
# showing the headline status twice - "Exporting target Exporting 19%-5%".
two_inverters = my_predbat.inverters
my_predbat.inverters = [two_inverters[0]]
my_predbat.args["num_inverters"] = 1
failed |= run_execute_test(
my_predbat,
"single_inverter_export_status",
export_window_best=export_window_best,
export_limits_best=export_limits_best,
set_charge_window=True,
set_export_window=True,
soc_kw=100,
assert_status="Exporting",
assert_status_extra=" target 100%-0%",
assert_force_export=True,
assert_discharge_start_time_minutes=my_predbat.minutes_now,
assert_discharge_end_time_minutes=my_predbat.minutes_now + 60 + 1,
assert_immediate_soc_target=0,
)
my_predbat.inverters = two_inverters
my_predbat.args["num_inverters"] = 2
if failed:
return failed

failed |= run_execute_test(
my_predbat,
"no_discharge_car_demand1",
Expand Down
60 changes: 59 additions & 1 deletion apps/predbat/tests/test_execute_multi_inverter_status.py
Original file line number Diff line number Diff line change
Expand Up @@ -13,7 +13,7 @@
overwrite, which silently hid genuine cross-inverter disagreement (e.g. real cross-charging).
"""

from execute import resolve_multi_inverter_status
from execute import build_status_extra, resolve_multi_inverter_status


def test_multi_inverter_status(my_predbat):
Expand Down Expand Up @@ -98,4 +98,62 @@ def test_multi_inverter_status(my_predbat):
print(" ERROR: expected 'Calibration' to override a stale core state left by an earlier inverter, got {!r}".format(result))
failed = True

failed |= test_build_status_extra()

return failed


def test_build_status_extra():
"""Verify the per-inverter status detail text only labels segments when inverters disagree.

#4466 began labelling every segment with that inverter's own state so a mixed fleet could be
read. The label is redundant when the whole fleet agrees, because the headline status the detail
is appended to already says it - a single-inverter export showed
"Exporting target Exporting 19%-5%" in v8.48.4.
"""
failed = False
print("**** Testing build_status_extra ****")

print("Test: no inverter recorded a detail segment - empty text")
result = build_status_extra([])
if result != "":
print(" ERROR: expected '' with no segments, got {!r}".format(result))
failed = True

print("Test: single inverter exporting - no repeated label (regression, GH v8.48.4)")
result = build_status_extra([(0, "target", "Exporting", "19%-5%")])
if result != " target 19%-5%":
print(" ERROR: expected ' target 19%-5%', got {!r}".format(result))
failed = True

print("Test: single inverter freeze exporting - uses its own lead word, still unlabelled")
result = build_status_extra([(0, "current SoC", "Freeze exporting", "19%")])
if result != " current SoC 19%":
print(" ERROR: expected ' current SoC 19%', got {!r}".format(result))
failed = True

print("Test: multiple inverters all in the same state - joined, still unlabelled")
result = build_status_extra([(0, "target", "Charging", "50%-80%"), (1, "target", "Charging", "60%-80%")])
if result != " target 50%-80% / 60%-80%":
print(" ERROR: expected ' target 50%-80% / 60%-80%', got {!r}".format(result))
failed = True

print("Test: inverters in different states - every segment labelled so the fleet can be read")
result = build_status_extra([(0, "target", "Charging", "90%-100.0%"), (1, "target", "Hold charging", "100%-100.0%")])
if result != " target Charging 90%-100.0% / Hold charging 100%-100.0%":
print(" ERROR: expected labelled mixed-fleet text, got {!r}".format(result))
failed = True

print("Test: cross-charging (charge and export at once) - labelled, as the headline says neither")
result = build_status_extra([(0, "target", "Charging", "50%-80%"), (1, "target", "Exporting", "50%-5%")])
if result != " target Charging 50%-80% / Exporting 50%-5%":
print(" ERROR: expected labelled cross-charging text, got {!r}".format(result))
failed = True

print("Test: only a non-zero inverter recorded a segment - separator used, no lead word")
result = build_status_extra([(1, "target", "Exporting", "19%-5%")])
if result != " / 19%-5%":
print(" ERROR: expected ' / 19%-5%', got {!r}".format(result))
failed = True

return failed
Loading