148 changes: 108 additions & 40 deletions apps/predbat/inverter.py
Original file line number Diff line number Diff line change
Expand Up @@ -359,6 +359,9 @@ def __init__(self, base, id=0, quiet=False):
self.track_discharge_end = "00:00:00"
self.idle_start_minutes = 0
self.idle_end_minutes = 0
# Last export schedule (start, end, enabled) Predbat actually committed to this inverter.
# None means nothing has been committed yet in this run, so the next call commits once.
self.last_export_schedule_committed = None

self.inverter_type = self.base.get_arg("inverter_type", "GE", indirect=False, index=self.id)
# An assumed type is not a chosen one. The user-facing "source returned no data" warnings
Expand Down Expand Up @@ -2073,7 +2076,7 @@ def adjust_battery_target(self, soc, isCharging=False, isExporting=False):

# For inverters that need a button press to apply changes (e.g., Fox), press the button now
if self.inv_time_button_press:
self.press_and_poll_button()
self.press_and_poll_button(side="charge")

if self.base.set_inverter_notify:
self.base.call_notify(f"{self.base.prefix.capitalize()}: Inverter {self.id} Target SoC has been changed to {soc}% at {self.base.time_now_str()}")
Expand Down Expand Up @@ -2447,7 +2450,7 @@ def adjust_pause_mode(self, pause_charge=False, pause_discharge=False):

self.base.log("Inverter {} set pause mode to {}".format(self.id, new_pause_mode))

def adjust_inverter_mode(self, force_export):
def adjust_inverter_mode(self, force_export, changed_start_end=False):
"""
Adjust inverter mode between force export and Demand mode (ECO)

Expand All @@ -2465,6 +2468,10 @@ def adjust_inverter_mode(self, force_export):

"""
inverter_mode_configured = "inverter_mode" in self.base.args
if changed_start_end:
# XXX: Workaround for GivTCP window state update time to take effort
self.base.log("Sleeping (workaround) as start/end of discharge window was just adjusted")
self.sleep(30)
old_inverter_mode = self.base.get_arg("inverter_mode", index=self.id)

if not self.inv_has_fox_inverter_mode and not self.inv_has_ge_eco_toggle:
Expand Down Expand Up @@ -2628,6 +2635,12 @@ def adjust_force_export(self, force_export, new_start_time=None, new_end_time=No
self.log("Warn: Inverter {} unable read discharge window as neither REST, discharge_start_time or discharge_start_hour are set".format(self.id))
return False

# Whether the caller asked us to manage the export times at all this cycle. execute.py calls
# adjust_force_export(False) with no times whenever nothing is being exported, which is a
# different thing from both an explicit caller-supplied window and the plain-GS midnight
# disable window synthesised below.
times_supplied = (new_start_time is not None) or (new_end_time is not None)

# Start time to correct format
if new_start_time:
new_start_time += timedelta(seconds=self.base.inverter_clock_skew_discharge_start * 60)
Expand Down Expand Up @@ -2662,9 +2675,11 @@ def adjust_force_export(self, force_export, new_start_time=None, new_end_time=No
if self.inv_charge_control_immediate:
self.enable_charge_discharge_with_time_current("discharge", False)

schedule_write_ok = True

# Turn off scheduled discharge
if not force_export and old_discharge_enable:
self.write_and_poll_switch("scheduled_discharge_enable", self.base.get_arg("scheduled_discharge_enable", indirect=False, index=self.id), False)
schedule_write_ok = self.write_and_poll_switch("scheduled_discharge_enable", self.base.get_arg("scheduled_discharge_enable", indirect=False, index=self.id), False) and schedule_write_ok
self.log("Inverter {} Turning off scheduled export".format(self.id))

self.base.log("Inverter {} Adjust force export to {}, change times from {} - {} to {} - {}".format(self.id, force_export, old_start, old_end, new_start, new_end))
Expand All @@ -2684,25 +2699,27 @@ def adjust_force_export(self, force_export, new_start_time=None, new_end_time=No
# Always write to this as it is the GE default
changed_start_end = True
entity_discharge_start_time_id = self.base.get_arg("discharge_start_time", indirect=False, index=self.id)
self.write_and_poll_option("discharge_start_time", entity_discharge_start_time_id, new_start)
schedule_write_ok = self.write_and_poll_option("discharge_start_time", entity_discharge_start_time_id, new_start) and schedule_write_ok

if self.inv_charge_time_format == "H M":
# If the inverter uses hours and minutes then write to these entities too
# If the entity is a time entity (e.g. for FB00 firmware), write the full time string instead of just the integer component
start_hour_id = self.base.get_arg("discharge_start_hour", indirect=False, index=self.id)
if start_hour_id and isinstance(start_hour_id, str) and start_hour_id.startswith("time."):
self.write_and_poll_option("discharge_start_hour", start_hour_id, new_start)
else:
self.write_and_poll_option("discharge_start_hour", start_hour_id, int(new_start[:2]))
schedule_write_ok = self.write_and_poll_option("discharge_start_hour", start_hour_id, new_start) and schedule_write_ok
elif start_hour_id:
schedule_write_ok = self.write_and_poll_option("discharge_start_hour", start_hour_id, int(new_start[:2])) and schedule_write_ok
start_minute_id = self.base.get_arg("discharge_start_minute", indirect=False, index=self.id)
if start_minute_id and isinstance(start_minute_id, str) and start_minute_id.startswith("time."):
self.write_and_poll_option("discharge_start_minute", start_minute_id, new_start)
else:
self.write_and_poll_option("discharge_start_minute", start_minute_id, int(new_start[3:5]))
schedule_write_ok = self.write_and_poll_option("discharge_start_minute", start_minute_id, new_start) and schedule_write_ok
elif start_minute_id:
schedule_write_ok = self.write_and_poll_option("discharge_start_minute", start_minute_id, int(new_start[3:5])) and schedule_write_ok
elif self.inv_charge_time_format == "H:M-H:M":
# If the inverter uses hours and minutes then write to these entities too
discharge_time = new_start + "-" + new_end
self.write_and_poll_option("discharge_time", self.base.get_arg("discharge_time", indirect=False, index=self.id), discharge_time)
discharge_time_id = self.base.get_arg("discharge_time", indirect=False, index=self.id)
if discharge_time_id:
schedule_write_ok = self.write_and_poll_option("discharge_time", discharge_time_id, discharge_time) and schedule_write_ok
else:
self.log("Warn: Inverter {} unable write export start time as neither REST or discharge_start_time are set".format(self.id))

Expand All @@ -2713,21 +2730,21 @@ def adjust_force_export(self, force_export, new_start_time=None, new_end_time=No
# Always write to this as it is the GE default
changed_start_end = True
entity_discharge_end_time_id = self.base.get_arg("discharge_end_time", indirect=False, index=self.id)
self.write_and_poll_option("discharge_end_time", entity_discharge_end_time_id, new_end)
schedule_write_ok = self.write_and_poll_option("discharge_end_time", entity_discharge_end_time_id, new_end) and schedule_write_ok

# If the inverter uses hours and minutes then write to these entities too
if self.inv_charge_time_format == "H M":
# If the entity is a time entity (e.g. for FB00 firmware), write the full time string instead of just the integer component
end_hour_id = self.base.get_arg("discharge_end_hour", indirect=False, index=self.id)
if end_hour_id and isinstance(end_hour_id, str) and end_hour_id.startswith("time."):
self.write_and_poll_option("discharge_end_hour", end_hour_id, new_end)
else:
self.write_and_poll_option("discharge_end_hour", end_hour_id, int(new_end[:2]))
schedule_write_ok = self.write_and_poll_option("discharge_end_hour", end_hour_id, new_end) and schedule_write_ok
elif end_hour_id:
schedule_write_ok = self.write_and_poll_option("discharge_end_hour", end_hour_id, int(new_end[:2])) and schedule_write_ok
end_minute_id = self.base.get_arg("discharge_end_minute", indirect=False, index=self.id)
if end_minute_id and isinstance(end_minute_id, str) and end_minute_id.startswith("time."):
self.write_and_poll_option("discharge_end_minute", end_minute_id, new_end)
else:
self.write_and_poll_option("discharge_end_minute", end_minute_id, int(new_end[3:5]))
schedule_write_ok = self.write_and_poll_option("discharge_end_minute", end_minute_id, new_end) and schedule_write_ok
elif end_minute_id:
schedule_write_ok = self.write_and_poll_option("discharge_end_minute", end_minute_id, int(new_end[3:5])) and schedule_write_ok
elif self.inv_charge_time_format == "H:M-H:M":
pass
else:
Expand Down Expand Up @@ -2758,23 +2775,60 @@ def adjust_force_export(self, force_export, new_start_time=None, new_end_time=No

# Change scheduled discharge enable
if force_export:
self.write_and_poll_switch("scheduled_discharge_enable", self.base.get_arg("scheduled_discharge_enable", indirect=False, index=self.id), True)
schedule_write_ok = self.write_and_poll_switch("scheduled_discharge_enable", self.base.get_arg("scheduled_discharge_enable", indirect=False, index=self.id), True) and schedule_write_ok
if not old_discharge_enable:
self.log("Inverter {} Turning on scheduled export".format(self.id))

if (new_end != old_end) or (new_start != old_start) or (force_export != old_discharge_enable) or changed_start_end:
# Whether the export schedule itself actually needs (re)committing to the inverter, as opposed
# to us merely having rewritten the time registers. For H M format those registers are rewritten
# every cycle as a write-reliability workaround (#1529), so changed_start_end is True on every
# cycle of a stable export window and must not be used to gate the commit - on Solis each button
# press zeroes the timed current registers (#4709), and it also triggers the 30s GivTCP sleep in
# adjust_inverter_mode. Tracking what we last committed keeps a stable window quiet while still
# committing once after a restart, when nothing has been committed yet (#4000).
# When neither side is managing times this cycle (e.g. idle cloud/GS_fb00 types), comparing None
# against the time the inverter still reports is never equal and would press the update button on
# every idle cycle for the rest of the day (#2328). Plain GS-style inverters still synthesise and
# manage a midnight disable window above, so their internally generated times must continue to count
# as a real schedule change that needs committing; GE's immediate-control disable path remains
# excluded from that synthetic-window rule, but still counts a caller-supplied window as managed.
times_managed = times_supplied or (not self.inv_has_discharge_enable_time and not self.inv_has_ge_inverter_mode and not force_export)
start_changed = times_managed and new_start != old_start
end_changed = times_managed and new_end != old_end
export_schedule = (new_start, new_end, force_export)
# Separately, whether the start/end times themselves actually moved - used below to gate the
# GivTCP settle sleep, which exists for the window write specifically ("start/end of discharge
# window was just adjusted"). schedule_changed alone is too broad for that: it also goes True on
# a bare scheduled_discharge_enable flip with the window untouched, which doesn't need settling.
times_changed = start_changed or end_changed
schedule_changed = times_changed or (force_export != old_discharge_enable)
if is_hm_format and export_schedule != self.last_export_schedule_committed:
# Only the H M path rewrites unconditionally, so only it needs the extra commit-once-per-run
# safety net; every other format already commits on a real change alone. Treat it as a real
# window write too, so the settle sleep still runs on this first post-restart commit.
schedule_changed = True
times_changed = True

if schedule_changed:
button_committed = True
if self.inv_time_button_press:
self.press_and_poll_button()
button_committed = self.press_and_poll_button(side="discharge")
committed = schedule_write_ok and button_committed
if committed:
# Only remember a commit that actually succeeded, otherwise a failed button press would
# be recorded as done and never retried until the schedule next changes on its own; the
# same applies if one of the time/switch writes failed before the button press.
self.last_export_schedule_committed = export_schedule
Comment thread
chalfontchubby marked this conversation as resolved.

# Force export, turn it on after we change the window
if force_export:
self.adjust_inverter_mode(force_export)
self.adjust_inverter_mode(force_export, changed_start_end=times_changed)
if not self.inv_has_charge_enable_time and (self.inv_output_charge_control == "current"):
if self.inv_charge_control_immediate:
self.enable_charge_discharge_with_time_current("discharge", True)

# Notify
if changed_start_end:
if schedule_changed and changed_start_end:
if self.base.set_inverter_notify:
self.base.call_notify(f"{self.base.prefix.capitalize()}: Inverter {self.id} Export time slot set to {new_start} - {new_end} at time {self.base.time_now_str()}")

Expand Down Expand Up @@ -2828,7 +2882,7 @@ def disable_charge_window(self, notify=True):
else:
# Press button if needed
if self.inv_time_button_press:
self.press_and_poll_button()
self.press_and_poll_button(side="charge")

# Updated cached status to disabled
# Don't do it if notify is not set as this is just a temporary call when setting the charge window
Expand Down Expand Up @@ -3246,14 +3300,22 @@ def adjust_charge_window(self, charge_start_time, charge_end_time, minutes_now):
if (new_start != old_start) or (new_end != old_end) or (old_charge_schedule_enable == "off"):
# For Solis inverters and fox we also have to press the update_charge_discharge button to send the times to the inverter
if self.inv_time_button_press:
self.press_and_poll_button()
self.press_and_poll_button(side="charge")

def press_and_poll_button(self):
def press_and_poll_button(self, side="both"):
"""
Press charge/discharge update button(s) for the inverter.
Priority:
1. charge_discharge_update_button
2. charge_update_button and discharge_update_button

`side` is one of "charge", "discharge" or "both" - the side that actually changed and
needs its update pressed. A single combined button (schedule_write_button or
charge_discharge_update_button) always covers both sides regardless, so `side` only
matters when separate charge_update_button/discharge_update_button entities are
configured (e.g. some Solis setups) - pressing the unrelated side's button there writes
an unnecessary command to the inverter (and, on hardware that counts these towards flash/
EEPROM wear, batpred#2328).
"""
success = True

Expand All @@ -3266,27 +3328,33 @@ def press_and_poll_button(self):
elif entity_id_charge_discharge_updated_button:
success = self._press_single_button_and_poll(entity_id_charge_discharge_updated_button)
else:
# Try separate charge and discharge buttons
charge_button = self.base.get_arg("charge_update_button", indirect=False, index=self.id)
discharge_button = self.base.get_arg("discharge_update_button", indirect=False, index=self.id)

if charge_button:
if not self._press_single_button_and_poll(charge_button):
success = False

if discharge_button:
if not self._press_single_button_and_poll(discharge_button):
success = False
# Try separate charge and discharge buttons - only press the one(s) relevant to `side`
if side in ("charge", "both"):
charge_button = self.base.get_arg("charge_update_button", indirect=False, index=self.id)
if charge_button:
if not self._press_single_button_and_poll(charge_button):
success = False

if side in ("discharge", "both"):
discharge_button = self.base.get_arg("discharge_update_button", indirect=False, index=self.id)
if discharge_button:
if not self._press_single_button_and_poll(discharge_button):
success = False

return success

def _press_single_toggle_button(self, entity_id):
"""
This is just a switch we can toggle to on, it will turn off again automatically.
"""
self.base.call_service_wrapper("switch/turn_on", entity_id=entity_id)
self.log(f"Inverter {self.id} pressed toggle button {entity_id}")
return True
result = self.base.call_service_wrapper("switch/turn_on", entity_id=entity_id)
state = self.base.get_state_wrapper(entity_id=entity_id)
if result or (isinstance(state, str) and state.lower() in ["on", "enable", "true"]) or (state is True):
self.log(f"Inverter {self.id} pressed toggle button {entity_id}")
return True
self.base.log(f"Warn: Inverter {self.id} Trying to press toggle button {entity_id} failed")
self.base.record_status(f"Warn: Inverter {self.id} Trying to press toggle button {entity_id} failed", had_errors=True)
return False

def _press_single_button_and_poll(self, entity_id):
"""
Expand Down
Loading
Loading