1 change: 1 addition & 0 deletions .cspell/custom-dictionary-workspace.txt
Original file line number Diff line number Diff line change
Expand Up @@ -555,6 +555,7 @@ Sergoe
sess
setattr
setdefault
setpoints
SFMB
sg05lp1
SIGALRM
Expand Down
165 changes: 130 additions & 35 deletions apps/predbat/solis.py
Original file line number Diff line number Diff line change
Expand Up @@ -76,6 +76,18 @@
SOLIS_CID_BATTERY_MAX_CHARGE_CURRENT = 7224
SOLIS_CID_BATTERY_MAX_DISCHARGE_CURRENT = 7226

# Nominal pack voltage selection (issue #5090). Thresholds come from 30 days of battery_voltage
# history across 30 LV systems plus a full inverterDetail from 14 of them:
# - no LV system exceeded 57.5V live, so a live reading above 60V is an HV pack;
# - the BMS-requested charge voltage separates the LV pack classes cleanly - 53.2V on every 15S
# pack that reported it, 56.5-58.4V on every 16S - so 55V sits in a 3.3V empty gap.
# The live voltage itself cannot be used to tell 15S from 16S: the classes overlap (a full 15S
# reaches 53.5V, a low 16S drops to 47.1V), which is why this is decided from the charge voltage.
SOLIS_HV_BATTERY_VOLTAGE = 60.0
SOLIS_LV_16S_CHARGE_VOLTAGE = 55.0
SOLIS_LV_15S_NOMINAL_VOLTAGE = 48.0
SOLIS_LV_16S_NOMINAL_VOLTAGE = 51.2

# Charge slot CIDs (base + slot_index for slots 1-6)
SOLIS_CID_CHARGE_ENABLE_BASE = 5916 # 5916-5921
SOLIS_CID_CHARGE_SOC_BASE = 5928 # 5928-5933
Expand Down Expand Up @@ -382,15 +394,16 @@ def initialize(self, api_key=None, api_secret=None, inverter_sn=None, automatic=
self.automatic = automatic
self.session = None
self.queued_events = []
# Fallback used only when an inverter has never reported a live batteryVoltage - matches
# the previous hard-coded assumption (issue #4493). get_nominal_voltage() below is the
# real source of truth once live data is available.
# Last-resort fallback, used only for an LV pack that reports no BMS charge voltage to be
# classified by - matches the previous hard-coded assumption (issue #4493).
# get_nominal_voltage() below is the real source of truth for the full priority order.
self.nominal_voltage = 48.0
self.nominal_voltage_last_known = {} # {inverter_sn: last measured battery voltage}
# Nominal *pack* voltage (e.g. cell count x nominal cell voltage), used for the capacity
# calculation only - deliberately distinct from the live measured voltage used for
# power/current conversions, since the two are not the same value on an HV battery
# be supplied via apps.yaml (solis_nominal_voltage) if capacity is to be accurate.
self.live_voltage_last_known = {} # {inverter_sn: last measured battery voltage}
self.nominal_voltage_reported = {} # {inverter_sn: conversion voltage already logged}
# Nominal *pack* voltage (e.g. cell count x nominal cell voltage) from apps.yaml. It is
# the preferred source for both the capacity calculation and the amp<->watt conversions,
# being the one figure available here that is an actual physical property rather than an
# inference from a measurement that moves with charge state.
try:
configured_pack_v = float(nominal_voltage) if nominal_voltage is not None else None
except (TypeError, ValueError):
Expand Down Expand Up @@ -1489,11 +1502,13 @@ async def automatic_config(self):
self.set_arg_auto("export_today", [f"sensor.{self.prefix}_solis_{device}_today_export_energy" for device in devices])

# Battery capacity and limits from cached details
# The arithmetic bug that made this sensor wrong by ~11x on HV batteries is fixed
# (issue #4493), but this stays commented out deliberately: without solis_nominal_voltage
# configured, battery_capacity falls back to the *live* measured voltage, which drifts
# with charge state - auto-binding soc_max to it would make soc_max itself wobble slightly
# cycle to cycle, which it never did before (the old 48V constant was wrong but static).
# The arithmetic bug that made this sensor wrong by ~11x on HV batteries is fixed (issue
# #4493), and since #5090 the sensor no longer wobbles cycle to cycle either - so the
# original reason this was commented out is gone. It stays off for a second one: without
# solis_nominal_voltage configured the capacity is still an *estimate* - the pack class is
# inferred from its BMS charge voltage, not stated - and
# set_arg_auto() defaults to overwrite=True, so enabling it would replace a correct
# hand-entered soc_max with an approximate one (noted in the log, but still replaced).
# User must still set soc_max manually in apps.yaml.
# self.set_arg("soc_max", [f"sensor.{self.prefix}_solis_{device}_battery_capacity" for device in devices])

Expand Down Expand Up @@ -1580,37 +1595,117 @@ def _calculate_max_currents(self, inverter_sn):

self.log(f"Solis API: Calculated max currents for {inverter_sn}: charge={max_charge}A, discharge={max_discharge}A")

def get_nominal_voltage(self, inverter_sn):
def get_live_battery_voltage(self, inverter_sn):
"""
Return the voltage to use for amp<->watt conversions for this inverter: the live measured
battery voltage if we have one, otherwise the last value we did measure, otherwise the
48V fallback. A hard-coded 48V here was issue #4493 - on a high-voltage battery it made
every derived power value wrong by roughly the ratio of the real pack voltage to 48V.
Return the live measured pack voltage, or the last one this inverter reported, or None.

This is the reading that moves with state of charge. It identifies an HV pack and is
published as a sensor for display, but must not be used for amp<->watt conversions on an
LV pack - see get_nominal_voltage().
"""
detail = self.inverter_details.get(inverter_sn, {})
try:
voltage = float(detail.get("batteryVoltage"))
except (ValueError, TypeError):
voltage = None
if voltage and voltage > 0:
self.nominal_voltage_last_known[inverter_sn] = voltage
self.live_voltage_last_known[inverter_sn] = voltage
return voltage
return self.nominal_voltage_last_known.get(inverter_sn, self.nominal_voltage)
return self.live_voltage_last_known.get(inverter_sn)

def get_bms_charge_voltage(self, inverter_sn):
"""
Return the BMS-requested charge voltage for this pack, or None if it isn't reported.

Unlike the live pack voltage this is a setting rather than a measurement, so it holds
still, and it is what distinguishes a 15S pack from a 16S one (53.2V vs 56.5-58.4V across
14 sampled systems). inverterDetail carries it top level as batteryAcvSet and per battery
as batteryList[].batteryChargingVoltage; the two agreed on every system sampled, so either
will do and the first non-zero one wins. Some inverters report neither (one S5-EH1P3.6K-L
had batteryChargingVoltage absent and batteryAcvSet 0.0), hence the None case.
"""
detail = self.inverter_details.get(inverter_sn, {})
candidates = [detail.get("batteryAcvSet")]
for entry in detail.get("batteryList") or []:
if isinstance(entry, dict):
candidates.append(entry.get("batteryChargingVoltage"))
for candidate in candidates:
try:
voltage = float(candidate)
except (ValueError, TypeError):
continue
if voltage > 0:
return voltage
return None

def get_nominal_voltage(self, inverter_sn):
"""
Return the voltage to use for amp<->watt conversions on this inverter.

The inverter holds its limits as currents (CID 7224/7226, and the per-slot currents), so
every watt value Predbat sees is derived. Deriving them from the live measured voltage made
a fixed 70A limit republish as anything from 3352W to 3726W as the pack moved with state of
charge, dragging battery_rate_max, the write tolerance computed from it and the read-back of
every rate setpoint along with it (issue #5090). Live voltage swings 10-14% over a month on
every system sampled, so this affected all of them, not just edge cases. In priority order:

1. solis_nominal_voltage from apps.yaml - the pack's real nominal voltage, and the only
source here that is a stated physical property rather than an inference;
2. a live reading above 60V means an HV pack, where the live voltage continues to be used
as it has been since issue #4493. No LV system sampled exceeded 57.5V. HV packs still
drift for want of field data to classify them by; solis_nominal_voltage fixes that;
3. otherwise an LV pack, classified by the BMS-requested charge voltage: 16S (51.2V
nominal) at or above 55V, 15S (48V nominal) below it. Both are settings rather than
measurements, so the result holds still across polls;
4. otherwise the 48V fallback, for a pack that reports no charge voltage at all.

The live reading cannot do the classifying itself, which is what made the first attempt at
this wrong: 15S packs average 49.3-50.4V and 16S 52.6-54.4V, but a full 15S reaches 53.5V
and a low 16S drops to 47.1V, so a single sample lands in the wrong class. batteryType is
no help either - it names the BMS protocol, not the pack, and PYLON_LV was reported by both
classes.
"""
if self.nominal_pack_voltage:
return self.nominal_pack_voltage
live_voltage = self.get_live_battery_voltage(inverter_sn)
if live_voltage and live_voltage > SOLIS_HV_BATTERY_VOLTAGE:
return live_voltage
charge_voltage = self.get_bms_charge_voltage(inverter_sn)
if charge_voltage:
nominal = SOLIS_LV_16S_NOMINAL_VOLTAGE if charge_voltage >= SOLIS_LV_16S_CHARGE_VOLTAGE else SOLIS_LV_15S_NOMINAL_VOLTAGE
self.report_nominal_voltage(inverter_sn, nominal, f"a BMS charge voltage of {charge_voltage}V")
return nominal
self.report_nominal_voltage(inverter_sn, self.nominal_voltage, "no BMS charge voltage being reported, so the pack class is unknown")
return self.nominal_voltage

def report_nominal_voltage(self, inverter_sn, nominal, reason):
"""Log the conversion voltage chosen for an LV pack, but only when it changes.

get_nominal_voltage() runs for every published entity, several times a second during a
publish cycle, so this cannot log unconditionally. Keyed on the value rather than a
once-only flag so that a pack being reclassified - which should not happen, and is worth
seeing if it does - is still reported.
"""
if self.nominal_voltage_reported.get(inverter_sn) == nominal:
return
self.nominal_voltage_reported[inverter_sn] = nominal
self.log(f"Solis API: {inverter_sn} will use {nominal}V for amp<->watt conversions, from {reason} - set solis_nominal_voltage in apps.yaml to state the pack's nominal voltage directly")

def get_capacity_voltage(self, inverter_sn):
"""
Return the configured nominal pack voltage to use for the battery capacity calculation,
or None if solis_nominal_voltage isn't set. This is deliberately NOT the same value as
get_nominal_voltage() (the live measured voltage): capacity should use the nominal pack
voltage (a fixed physical property, e.g. cell count x nominal cell voltage), and the live
value drifts with charge state.
or None if solis_nominal_voltage isn't set. Separate from get_nominal_voltage() only so
that the caller can tell a configured value from an inferred one and flag the published
capacity accordingly - when solis_nominal_voltage *is* set, both return it.

Note on the None case: DEYE's equivalent (nominal_pack_voltage()/derive_battery_capacity()
in deye.py) refuses to publish a capacity at all rather than guess, on the basis that a
wrong soc_max source is worse than none. Solis instead falls back to the live voltage and
flags the result unreliable (see the caller in publish_entities) so existing installs that
already had this sensor (using the old, worse, hard-coded 48V) don't lose it outright -
a different tradeoff than DEYE's for the same underlying problem, worth reviewer scrutiny.
wrong soc_max source is worse than none. Solis instead falls back to get_nominal_voltage()
- since #5090 an inferred nominal rather than a live reading on an LV pack, so the published
capacity holds still - and flags it unreliable (see the caller in publish_entities) so that
existing installs which already had this sensor (using the old, worse, hard-coded 48V)
don't lose it outright. A different tradeoff than DEYE's for the same underlying problem,
worth reviewer scrutiny.
"""
return self.nominal_pack_voltage

Expand Down Expand Up @@ -2492,10 +2587,10 @@ async def publish_entities(self):
# is the per-battery Ah rating, same as the max charge/discharge current CIDs
# handled in _calculate_max_currents() above.
battery_count = self.parallel_battery_count.get(inverter_sn, 1)
# Prefer the configured nominal pack voltage. Without it, fall back to the live
# measured voltage rather than dropping the sensor entirely - existing installs
# already have this sensor published (albeit with the old, worse, hard-coded 48V
# figure) and losing it outright without any migration path was judged too
# Prefer the configured nominal pack voltage. Without it, fall back to the
# inferred conversion voltage rather than dropping the sensor - existing
# installs already have this sensor published (albeit with the old, worse,
# hard-coded 48V figure) and losing it outright with no migration path was too
# disruptive. It's flagged as unreliable via the reliable/voltage_source
# attributes and a warning instead, matching neither "guess silently" nor "go
# unavailable silently" - reviewers may want a different tradeoff here.
Expand All @@ -2509,8 +2604,8 @@ async def publish_entities(self):
if inverter_sn not in self.capacity_voltage_warned:
self.capacity_voltage_warned.add(inverter_sn)
self.log(
f"Warn: Solis API {inverter_name} battery capacity is estimated from the live measured voltage ({capacity_voltage}V), which varies with charge state - "
"set solis_nominal_voltage in apps.yaml for an accurate, stable value (this warning will not repeat)"
f"Warn: Solis API {inverter_name} battery capacity is estimated using an inferred pack voltage ({capacity_voltage}V), which is only within a few percent of the pack's true nominal voltage - "
"set solis_nominal_voltage in apps.yaml for an accurate value (this warning will not repeat)"
)
battery_capacity_kWh = battery_capacity_ah * battery_count * capacity_voltage / 1000.0
entity_id = f"sensor.{prefix}_solis_{inverter_sn_lower}_battery_capacity"
Expand All @@ -2524,7 +2619,7 @@ async def publish_entities(self):
"state_class": "measurement",
"icon": "mdi:battery" if reliable else "mdi:battery-alert",
"reliable": reliable,
"voltage_source": "configured (solis_nominal_voltage)" if reliable else "estimated from the live measured voltage - set solis_nominal_voltage in apps.yaml for an accurate, stable value",
"voltage_source": "configured (solis_nominal_voltage)" if reliable else "estimated using an inferred pack voltage - set solis_nominal_voltage in apps.yaml for an accurate value",
},