2 changes: 2 additions & 0 deletions apps/predbat/config.py
Original file line number Diff line number Diff line change
Expand Up @@ -2712,6 +2712,8 @@
"inverter_limit_override": {"type": "sensor_list", "sensor_type": "integer", "modify": False, "zero": False, "entries": "num_inverters"},
"battery_rate_max": {"type": "sensor_list", "sensor_type": "float", "modify": False, "zero": False, "entries": "num_inverters"},
"export_limit": {"type": "sensor_list", "sensor_type": "float", "entries": "num_inverters"},
# Whole-site diagnostic threshold in W, not a per-inverter limit or a control setting.
"import_limit": {"type": "float", "zero": True},
"inverter_battery_rate_min": {"type": "integer", "zero": False, "entries": "num_inverters"},
"inverter_reserve_max": {"type": "integer", "zero": False, "entries": "num_inverters"},
"battery_charge_power_curve": {"type": "int_float_dict", "or_auto": True},
Expand Down
2 changes: 2 additions & 0 deletions apps/predbat/const.py
Original file line number Diff line number Diff line change
Expand Up @@ -101,6 +101,8 @@
INVERTER_QUICK_UPDATE_SECONDS = 60 # Minimum seconds between quick inverter data updates, also the balance re-apply interval
INVERTER_LIMIT_DEFAULT_W = 7500.0 # Standing inverter AC limit when the user has not configured inverter_limit
EXPORT_LIMIT_DEFAULT_W = 99999.0 # Standing export limit when the user has not configured export_limit - effectively unlimited
# Whole-site diagnostic threshold in W; 0 disables reporting. Not a control or optimiser constraint.
IMPORT_LIMIT_DEFAULT_W = 0.0
PREDBAT_MAX_CARS = 8 # Matches PK_MAX_CARS in prediction_kernel.cpp and the car_charging_rate/_1../_7 config items - the hard ceiling on num_cars
# A car_charging_now sensor that reports a charging power (in W, after unit conversion) rather than
# on/off counts as charging from this power: above a charger's standby draw, below the smallest charge
Expand Down
15 changes: 15 additions & 0 deletions apps/predbat/fetch.py
Original file line number Diff line number Diff line change
Expand Up @@ -19,6 +19,7 @@
"""

from datetime import datetime, timedelta
from math import isfinite
from utils import minutes_to_time, str2time, dp1, dp2, dp3, dp4, time_string_to_stamp, minute_data, get_now_from_cumulative, MinuteArray
from const import (
MINUTE_WATT,
Expand All @@ -36,6 +37,7 @@
CLOUD_WINDOW_MINUTES,
CLOUD_ARRAY_MARGIN,
PV_ARRAY_KWP_UNKNOWN,
IMPORT_LIMIT_DEFAULT_W,
)
from predbat_metrics import metrics
from futurerate import FutureRate
Expand Down Expand Up @@ -82,6 +84,18 @@ class Fetch:
and other sensor inputs. Converts all data to per-minute dictionaries.
"""

def fetch_import_limit(self):
"""Read one finite, non-negative site threshold in W; never coerce bad input to off.

This first stage accepts a literal YAML number only. Read the raw argument because
get_arg with a numeric default coerces invalid values to that default, hiding errors.
The generic float schema does not reject lists, booleans or non-finite values.
"""
value = self.args.get("import_limit", IMPORT_LIMIT_DEFAULT_W)
if type(value) not in (int, float) or not isfinite(value) or value < 0:
raise ValueError("import_limit must be a finite non-negative scalar number in W (0 disables diagnostics)")
return float(value)

def get_cloud_factor(self, minutes_now, pv_data, pv_data10):
"""
Work out approximated cloud factor
Expand Down Expand Up @@ -3746,6 +3760,7 @@ def fetch_config_options(self):
self.inverter_loss = 1.0 - self.get_arg("inverter_loss")
self.inverter_hybrid = self.get_arg("inverter_hybrid")
self.pv_ac_limit = self.get_arg("pv_ac_limit", 0.0) / MINUTE_WATT
self.import_limit = self.fetch_import_limit()
self.inverter_freeze_export_discharge_rate = max(self.get_arg("inverter_freeze_export_discharge_rate", 0.0), 0.0) / MINUTE_WATT
self.log("Freeze Export discharge rate configured: {:.0f} W".format(self.inverter_freeze_export_discharge_rate * MINUTE_WATT))
self.base_load = self.get_arg("base_load", 100) / 1000.0
Expand Down
27 changes: 27 additions & 0 deletions apps/predbat/plan.py
Original file line number Diff line number Diff line change
Expand Up @@ -5105,6 +5105,32 @@ def optimise_charge_windows_reset(self, reset_all):
else:
self.export_limits_best[window_n] = pack_export_limit(EXPORT_MODE_IDLE)

def publish_import_limit_diagnostics(self, pred):
"""Publish the final best forecast's diagnostic, never an enforcement/feasibility claim."""
attributes = {
"friendly_name": "Best plan grid import limit diagnostic",
"icon": "mdi:transmission-tower-import",
"scope": "whole_site",
"enforced": False,
"limit_w": self.import_limit,
"peak_w": None,
"excess_kwh": None,
"minutes_over": None,
"first_exceeded": None,
"step_minutes": None,
"checked_minutes": 0,
"start": None,
"end": None,
}
state = "disabled" if self.import_limit == 0 else "unavailable"
diagnostic = getattr(pred, "import_limit_diagnostics", None)
if self.import_limit > 0 and diagnostic and diagnostic["limit_w"] == self.import_limit and diagnostic["checked_minutes"] == pred.forecast_minutes and pred.forecast_minutes > 0:
attributes.update(diagnostic)
attributes["peak_w"] = round(diagnostic["peak_w"], 3)
attributes["excess_kwh"] = round(diagnostic["excess_kwh"], 6)
state = "exceeded" if diagnostic["minutes_over"] else "within_limit"
self.dashboard_item(self.prefix + ".best_import_limit", state=state, attributes=attributes)

def run_prediction(self, charge_limit, charge_window, export_window, export_limits, pv_scenario, end_record, save=None, step=PREDICT_STEP):
"""
Run a prediction scenario given a charge limit, options to save the results or not to HA entity
Expand Down Expand Up @@ -5400,6 +5426,7 @@ def run_prediction(self, charge_limit, charge_window, export_window, export_limi

if save and save == "best":
self.log("Saving plan best values to HA entities")
self.publish_import_limit_diagnostics(pred)
self.dashboard_item(
self.prefix + ".best_battery_hours_left",
state=dp2(hours_left),
Expand Down
2 changes: 2 additions & 0 deletions apps/predbat/predbat.py
Original file line number Diff line number Diff line change
Expand Up @@ -503,6 +503,8 @@ def reset(self):
self.current_charge_limit_kwh = 0.0
self.inverter_limit = 0.0
self.export_limit = 0.0
# Whole-site diagnostic threshold, stored in W (not kWh/minute). 0 disables reporting.
self.import_limit = 0.0
self.charge_limit = []
self.charge_limit_best = []
self.charge_window = []
Expand Down
37 changes: 36 additions & 1 deletion apps/predbat/prediction.py
Original file line number Diff line number Diff line change
Expand Up @@ -18,7 +18,7 @@
"""

from datetime import timedelta
from const import PREDICT_STEP, PV_SCENARIO_PV10, PV_SCENARIO_PV90, RUN_EVERY, TIME_FORMAT, EXPORT_LIMIT_FREEZE, EXPORT_LIMIT_IDLE, EXPORT_MODE_TARGET, EXPORT_MODE_FREEZE, EXPORT_MODE_IDLE
from const import PREDICT_STEP, PV_SCENARIO_PV10, PV_SCENARIO_PV90, RUN_EVERY, TIME_FORMAT, EXPORT_LIMIT_FREEZE, EXPORT_LIMIT_IDLE, EXPORT_MODE_TARGET, EXPORT_MODE_FREEZE, EXPORT_MODE_IDLE, MINUTE_WATT

from utils import (
remove_intersecting_windows,
Expand Down Expand Up @@ -172,6 +172,8 @@ def __init__(
self.inverter_hybrid = base.inverter_hybrid
self.inverter_limit = base.inverter_limit
self.export_limit = base.export_limit
# Diagnostic only, in W. It does not modify dispatch, costs or candidate selection.
self.import_limit = getattr(base, "import_limit", 0.0)
self.pv_ac_limit = base.pv_ac_limit
self.battery_rate_min = base.battery_rate_min
self.battery_rate_max_charge = base.battery_rate_max_charge
Expand Down Expand Up @@ -520,6 +522,10 @@ def run_prediction(self, charge_limit, charge_window, export_window, export_limi
if save and self.pending_batch:
self.flush_batch()

# Only saved Python runs report this diagnostic. Clear it even on a cache/kernel return
# so a later trial cannot appear to have inherited a successful check of a different plan.
self.import_limit_diagnostics = None

# The cache key is only wanted when the cache is actually in play - a saving run always
# simulates - so it is not computed otherwise. Building it as one tuple hash keeps the
# per-window hashing in C rather than looping in Python, which matters because this runs on
Expand Down Expand Up @@ -578,6 +584,19 @@ def run_prediction(self, charge_limit, charge_window, export_window, export_limi
predict_pv_power = {}
predict_state = {}
predict_grid_power = {}
import_diagnostics = None
if save and self.import_limit > 0:
import_diagnostics = {
"limit_w": self.import_limit,
"peak_w": 0.0,
"excess_kwh": 0.0,
"minutes_over": 0,
"first_exceeded": None,
"step_minutes": step,
"checked_minutes": 0,
"start": (self.midnight_utc + timedelta(minutes=self.minutes_now)).strftime(TIME_FORMAT),
"end": (self.midnight_utc + timedelta(minutes=self.minutes_now + self.forecast_minutes)).strftime(TIME_FORMAT),
}
predict_load_power = {}
predict_iboost = {}
predict_carbon_g = {}
Expand Down Expand Up @@ -1361,6 +1380,21 @@ def run_prediction(self, charge_limit, charge_window, export_window, export_limi
# The car in a dispatch that has gone away is met by the grid (or PV surplus), never the battery
diff += car_gone_kwh

# Observe the raw whole-site AC balance, before presentation rounding. Do not clamp
# grid demand, invent battery discharge, or change a candidate's cost. This covers the
# full displayed forecast, including steps after the optimiser's end_record boundary.
if import_diagnostics is not None:
# A modelled car outside the house CT is absent from diff; it still shares the
# grid connection. Net it against any surplus, without counting metered cars twice.
import_w = max(diff + car_load_energy_bypass, 0.0) * MINUTE_WATT / step
import_diagnostics["peak_w"] = max(import_diagnostics["peak_w"], import_w)
import_diagnostics["checked_minutes"] += step
if import_w - self.import_limit > 1e-6:
import_diagnostics["excess_kwh"] += (import_w - self.import_limit) * step / MINUTE_WATT
import_diagnostics["minutes_over"] += step
if import_diagnostics["first_exceeded"] is None:
import_diagnostics["first_exceeded"] = stamp

# Metric keep - pretend the battery is empty and you have to import instead of using the battery
if best_soc_keep > 0 and soc <= best_soc_keep:
metric_keep += (best_soc_keep - soc) * import_rate * keep_minute_scaling * step / 60.0
Expand Down Expand Up @@ -1474,6 +1508,7 @@ def run_prediction(self, charge_limit, charge_window, export_window, export_limi
minute += step

hours_left = minute_left / 60.0
self.import_limit_diagnostics = import_diagnostics
if self.debug_enable or save:
self.hours_left = hours_left
self.final_car_soc = final_car_soc
Expand Down
1 change: 1 addition & 0 deletions apps/predbat/prediction_kernel.py
Original file line number Diff line number Diff line change
Expand Up @@ -897,6 +897,7 @@ def reset_kernel_run_state(pred):
pred.predict_carbon_best = {}
pred.predict_clipped_best = {}
pred.predict_car_hold_best = {}
pred.import_limit_diagnostics = None
pred.iboost_running = False
pred.iboost_running_solar = False
pred.iboost_running_full = False
Expand Down
Loading