Home Assistant integration for Voltie chargers. Talks to the charger over your LAN using its local HTTP API.
The dashboard card is a separate repository: voltie-eu/lovelace-voltie-charger-card.
Built against HTTP API v5.0. Features the charger's firmware doesn't provide are hidden or reported unavailable rather than failing, so older firmware keeps working.
- Per-phase voltage, current and power sensors.
- Total charge power, session energy, session duration.
- EVSE state sensor.
- DLM and IPM meter readings.
- Binary sensors for car connected and charging in progress.
- Switches for start/stop, autostart, display, LEDs, buzzer, out of service and forced single-phase charging.
- Number entities for the charging current limit and the load-management and grid-control parameters.
- Selects for the load-management mode and access mode.
- Buttons to reboot the charger and to run RFID learn mode.
- Services for the display, the rear LED and RFID tag management.
- Diagnostics download with credentials redacted.
- mDNS auto-discovery.
- Home Assistant 2025.1 or newer.
- HACS installed.
- A Voltie Charger on your LAN with HTTP API enabled in the Voltie mobile app. If you set a username and password, you'll need them during setup.
HACS is the recommended way — it handles updates for you.
- Open HACS in the sidebar.
- Open the ⋮ menu → Custom repositories.
- Fill in the dialog:
- Repository:
https://github.com/voltie-eu/homeassistant-voltie_charger - Type: Integration
- Repository:
- Click Add.
- Back on the HACS main page, search for
Voltie Charger. - Click the result and click Download.
- Confirm the latest version and click Download again.
- Restart Home Assistant.
After the restart, the charger is usually found automatically via mDNS within a minute.
- Go to Settings → Devices & services.
- A Voltie Charger appears under Discovered with the charger's ID.
- Click Add.
- If the charger has credentials set, enter the Username and Password. Otherwise the form submits directly.
- Click Submit, then Finish.
If it doesn't appear (mDNS is often blocked on VLAN-isolated networks), add it manually: Settings → Devices & services → Add integration → Voltie Charger, then enter the charger's IP address and credentials.
Each charger creates one device with about 60 entities. The main ones:
| Entity | Purpose |
|---|---|
sensor.<name>_charge_power |
Live charging power (kW). |
sensor.<name>_session_energy |
Session energy (kWh). |
sensor.<name>_session_charge_time |
Session charge time. |
sensor.<name>_evse_state |
EVSE state. |
sensor.<name>_active_phases |
Phases used by the current session. |
sensor.<name>_phases_wired |
Phases wired into the charger. |
sensor.<name>_hardware_current_limit |
Highest current the hardware supports (A). |
binary_sensor.<name>_car_connected |
Plug detection. |
binary_sensor.<name>_charging |
Charging in progress. |
switch.<name>_charging_enabled |
Start / stop. |
switch.<name>_out_of_service |
Take the charger out of service. |
switch.<name>_force_single_phase_charging |
Force single-phase charging. |
number.<name>_maximum_charging_current |
Charging current limit (A). |
select.<name>_load_management_mode |
Off / dynamic / eco / green / grid control. |
select.<name>_access_mode |
Home charger, with or without RFID. |
button.<name>_reboot_charger |
Reboot the charger. |
Per-phase voltage / current / power, DLM / IPM readings, the grid-control parameters and the RFID reader status are exposed as individual entities. Some diagnostic entities are disabled by default — enable them from the device page.
number.<name>_maximum_charging_current takes its upper bound from the charger's own current_hw_limit, capped at the 32 A the API accepts.
| Action | Purpose |
|---|---|
voltie_charger.display_text |
Scroll a message across the charger's display. |
voltie_charger.set_rear_led |
Set the rear LED colour and brightness for a period. |
voltie_charger.start_charging |
Start a session, optionally recording an RFID tag. |
voltie_charger.add_rfid_tag |
Add a tag to the charger's stored list. |
voltie_charger.modify_rfid_tag |
Change a stored tag's name, comment or enabled flag. |
voltie_charger.delete_rfid_tag |
Remove a stored tag. |
voltie_charger.list_rfid_tags |
Return the stored tags as action response data. |
voltie_charger.start_rfid_learn |
Start learn mode with a timeout and tag count. |
Each action targets one charger device. The RFID actions require API v5 firmware.
RFID tag IDs must be hexadecimal (0-9, A-F), 8 to 20 characters. The API documentation describes a wider character set, but the firmware rejects anything else, so these actions validate it up front rather than letting the charger return a generic error.
Existing entities keep their entity IDs, so dashboards and automations continue to work. Two cosmetic details are worth knowing:
- The
phasessensor was renamed to Phases wired, because the API clarified that the field means phases wired into the charger rather than phases in use. On an upgraded install it keeps its original..._phases_in_useentity ID, so that ID no longer matches its name. The new session-phase sensor is Active phases. - New entities may pick up an area prefix in their entity ID (for example
sensor.garage_voltie_charger_1234_active_phases) while pre-existing ones do not, because Home Assistant derives IDs from the device's area at creation time. Removing and re-adding the integration gives a consistent set, at the cost of losing entity history.
The integration adapts to what the charger reports:
- Configuration entities whose
/configkey is missing read as unavailable. - RFID entities are only created when the charger answers
GET /rfid/status. After a firmware upgrade, reload the integration to pick them up. /extrascommands that the firmware rejects as unknown produce an error telling you to update the charger.
sensor.<name>_api_version reports the charger's major API version, which is useful in support tickets.
Authentication fails. The credentials are the ones set inside the charger's HTTP API config, not your Voltie cloud account.
Charger not discovered. Confirm the HTTP API is enabled. Add the charger manually by IP if your network blocks mDNS.
Entities go unavailable. The integration retries with backoff. If it persists, check the charger is powered and on the network.
RFID entities are missing. They need API v5 firmware. Check sensor.<name>_api_version, then reload the integration after updating the charger.
"Not master" errors on RFID actions. The charger is a secondary unit in a prepaid-RFID cluster — send the action to the master unit instead.